Service manual

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
7
93
5
5. Press the “-” key. The display will blink “totL” for 3 seconds and
then display the total number of
regenerations this control has cycled through.
6. Press the “-” key. The display will blink “daYS” for 3 seconds
and then display the number of days since last regeneration.
Note: Pressing the “+” key at any time brings back to manual cycling.
Pressing “Status” will Exit the programming menu.
Board Diagnostics
To enter the circuit board test mode, follow the procedure listed below:
Service or Test Mode
Press and hold the “STATUS” key until “dIP 1” appears in the display. “dIP
1” will blink for 3 seconds and then the display will show the status of this
option (SEr or tES). Toggle the feature with the “+” or “-” key.
Note: Pressing “STATUS” after changing option to test mode will place the
control in test mode. After testing is complete press and hold “STATUS” for
3 seconds to exit. Placing the unit in test mode will not change any of the
programmed values. (Refer to the Service Manual for test menu).
1. Press the status key. The software version will be displayed.
2. Press the status key. “TEST” will flash for 3 seconds, then all segments
of the display will be lit.
Note: If STATUS is pressed when “TEST” is flashing, it will proceed to
the next step.
E5 3.9