Operating instructions

10 CULLIGAN SILVER SERIES
WATER SOFTENER
TABLE 1 - DRAIN LINE LENGTH AND HEIGHT LIMITATIONS
9-INCH MODELS
Average Water
Pressure Height of Drain Discharge Above Floor Upon Which Softener Sets
psi 4 in. 1 ft 2 ft 3 ft 4 ft 5 ft 6 ft 7 ft 8 ft 9 ft 10 ft
kPa 0.1 m 0.3 m 0.6 m 0.9 m 1.2 m 1.5 m 1.8 m 2.1 m 2.4 m 2.7 m 3.1 m
30 56 50 40 30 20 10
210 17.1 15.3 12.2 9.2 6.1 3.1
50 112 106 96 86 76 66 56 46 36 26 16
350 34.2 32.3 29.3 26.2 23.2 20.1 17.1 14.0 11.0 7.9 4.9
70 143 137 127 117 107 97 87 77 67 57 47
480 43.6 41.8 38.7 35.7 32.6 29.6 26.5 23.5 20.4 17.4 14.3
90 153 147 137 127 117 107 97 87 77 67 57
620 46.7 44.8 41.8 38.7 35.7 32.6 29.6 26.5 23.5 20.4 17.4
120 159 153 143 133 123 113 103 93 83 73 63
830 48.5 46.7 43.6 40.6 37.5 34.5 31.4 38.4 25.3 22.3 19.2
12-INCH MODELS
Average Water
Pressure Height of Drain Discharge Above Floor Upon Which Softener Sets
psi 4 in. 1 ft 2 ft 3 ft 4 ft 5 ft 6 ft 7 ft 8 ft 9 ft 10 ft
kPa 0.1 m 0.3 m 0.6 m 0.9 m 1.2 m 1.5 m 1.8 m 2.1 m 2.4 m 2.7 m 3.1 m
30 44 38 28 18
210 13.4 11.6 8.5 5.5
50 103 97 87 77 67 57 47 37 27 17 7
350 31.4 29.6 26.5 23.5 20.4 17.4 14.3 11.3 8.2 5.2 2.1
70 129 123 113 103 93 83 73 63 53 43 33
480 39.3 37.5 34.5 31.4 28.4 25.3 22.3 19.2 16.2 13.1 10.1
90 145 139 129 119 109 99 89 79 69 59 49
620 44.2 42.4 39.3 36.3 33.2 30.2 27.1 24.1 21.0 18.0 14.9
120 153 147 137 127 117 107 97 87 77 67 57
830 46.7 44.8 41.8 38.7 35.7 32.6 29.6 26.5 23.5 20.4 17.4