Operating instructions

Press to increase or
to decrease
Press to increase or
to decrease
Press to increase or
to decrease
Make sure the inlet water supply is turned off, then supply power to the timer. The display will power up flashing
"12:00 PM". After 1 minute the motor will energize and cycle the control, without stopping, to the home position.
This is required to ensure that the control is in the home position.
Press to increase or
to decrease
FIG. 12 - Circuit Board Display
Programming
14 CULLIGAN SILVER SERIES
WATER SOFTENER
The timer uses four buttons:
1. STATUS: Advance timer through display options.
2. UP ARROW: Increase the setting.
3. DOWN ARROW: Decrease the setting.
4. REGEN.: Initiate a manual regeneration.
SETTING THE MICROPROCESSOR
The microprocessor senses when it is installed as a Soft-Minder or Aqua-Sensor
®
control. Adding or removing any
connection to the board while power is on, or flipping any of the dip switches will automatically reset the
microprocessor to the factory settings.
1. With a flashing or blank display, pressing the status button twice will
move to the Time-of-Day adjustment. Adjust the time by using the up and
down arrows. A number “1” will appear at the bottom of the display while
in this mode.
2. Press status again, this displays the Time-of-Regeneration for delayed
units, adjust using the up and down arrows. A number “2” will appear at
the bottom of the display while in this mode.
3. Press status again, the number “3” will appear at the bottom of the display.
This setting is not used, and any changes made will not affect the operation
of the microprocessor.
4. Pressing status again will show the Salt Dosage. This can be adjusted
with the up and down arrows, the range is 3-15 lbs. for the 9” controls and
5-24 lbs. on 12” controls. A number “4” will appear at the bottom of the
display while in this mode.