Operating instructions

COMPONENT DESCRIPTION
The water conditioner is shipped from the factory in a minimum of four cartons. Remove all components from their
cartons and inspect them before starting installation.
Control Valve Assembly - Includes the 5-cycle regeneration control valve and the Accusoft
®
Microprocessor. Small
parts packages will contain additional installation hardware. Installation and Operations Instructions and an
Owners Guide are included.
Media Tank - Includes Tripl-Hull
media tank complete with Cullex
®
ion exchange resin, underbedding and outlet
manifold.
Salt Storage Tank Assembly - Includes salt storage container with support plate and Dubl-Safe
brine refill valve
and chamber.
Bypass Valve - Includes the Cul-Flo-Valv
®
, interconnecting couplings, and the screws necessary for assembly.
TOOLS AND MATERIALS
The following tools and supplies will be needed, depending on installation method. Observe all applicable codes.
All Installations
Safety glasses
Phillips screwdrivers, small and medium tip.
Gauge assembly (PN 00-3044-50 or equivalent)
Silicone lubricant (PN 00-4715-07 or equivalent) - DO NOT USE PETROLEUM-BASED LUBRICANTS
A bucket, preferably light-colored
Towels
Special Tools
Torch, solder and flux for sweat copper connections
Threading tools, pipe wrenches and thread sealer for threaded connections.
Saw, solvent and cement for plastic pipe connections.
Materials
Brine line, 5/16” (PN 00-3031-28 or equivalent)
Drain line, 1/2” (PN 00-3030-82, gray, semi-flexible; or PN 00-3319-46, black, semi-rigid; or equivalent)
Thread sealing tape
Pressure reducing valve (if pressure exceeds 125 psi [860 kPa], PN 00-4909-00 or equivalent)
Pipe and fittings suited to the type of installation
Water softener salt (rock, solar or pellet salt formulated specifically for water softeners)
APPLICATION
Water quality - Verify that raw water hardness and iron are within limits. Note the hardness for setting the salt
dosage and recharge frequency.
Pressure - If pressure exceeds 125 psi (860 kPa), install a pressure reducing valve (see materials checklist). On
private water systems, make sure the minimum pressure (the pressure at which the pump starts) is greater than 20
psi (140 kPa). Adjust the pressure switch if necessary.