Owner manual

PRODUCT MANUALPRODUCT MANUAL
2928
16X2 CHANNEL USB INTERFACE MODE 16X2 CHANNEL USB INTERFACE MODE
12.2.1. Mixer View
1
2
3
4
5
6
7
8
9
10
1. Monitor panning
2. Input level faders
3. Input level meters
4. Mute
5. Solo
6. Channel link
7. Main out level meters
8. Crossfader
9. USB connection indicator
10. Display device settings
12.2.2. Settings View: Synchronization Tab
Device Name
The device name eld controls what device name will appear in your DAW software. The default
name is “LR-16” but it can be modied to the name of your choosing.
Sample Rate
Click on this eld to select what sample rate you wish to operate the LP-16 at when using it as an
audio interface. Choices include:
44.1k Hz
48kHz
88.2kHz
96kHz
Sync Source Display
This eld displays the current synchronization source.
12.2.3. Settings View: Buffers Tab
The control panel’s buffers screen allows adjustment of the ASIO buffers used by your ASIO
compatible DAW software.
USB Streaming Mode
Adjust this value to set the basic mode of operation of the LR-16 drivers.
ASIO Buffer Depth
Adjust this setting to congure the size of the ASIO buffer, measured in samples.
When using an older, slower computer, you may need to set your latency value to a higher
amount. This will reduce the overhead to the computers CPU and allow your DAW session to run
more smoothly, but will result in a higher amount of delay between the original incoming audio
signal, and the DAW software
When using a newer, faster computer, the buffer depth can be set to a lower amount, and latency
will be minimized.
ASIO Dropout Statistics
This display eld indicates how many “drop-outs” have occurred, if any, with the currently selected
buffer settings.
Dropouts indicate that your computer’s CPU cannot keep up with the demand that is placed on
it by the current buffer depth. If any dropouts occur, increase the size of the buffer depth and / or
change the streaming mode until no more dropouts are reported.