Specifications

Page 10
8. Troubleshooting
Situation Check Point/s
Power LED does not illuminate when power is
ON.
1. Check the right adaptor is being used - 5V/2.6 A is
the correct adaptor.
2. Check all power connectors are plugged in correctly.
3. Press the power buttons to turn on the devices
After powering up Tx & Rx, the Link LEDs are
ashing quickly / slowly without displaying a
picture.
1. Ensure your connected screen is On, and has the
correct HDMI input selected, otherwise the Receiver
unit’s link LED will ash.
2. This is normal if the devices are pairing or learning,
the LED will ash slowly when it is carrying out a signal
conrmation. Once signal lock is conrmed the LED will
remain on.
3. If the LED ashes quickly for more than
3 minutes, perform an ID reset as described on page 3
of this manual.
4. If the LED ashes slowly for more than
3 minutes, check the input selection on the transmitter
and conrm a device is connected to that input.
The Link LED remains on but no image is dis-
played or an unexpected image is displayed.
1. Check if source’s resolution is supported, the device
can support up to 1080i and 1080p 24/30, please
make sure the source is sending a supported resolu-
tion, and conrm that your display can also accept that
resolution.
2. Check that both the source and the display are HDCP
compliant.
3. Check that the TV is on the correct AV channel.
4. Check all hdmi cables have a good physical con-
nection to the Rx/Tx units and connected sources and
display.
Input LEDs do not illuminate.
If the display connected to the receiver unit is not
turned on and set to the correct HDMI channel, the
input LEDs will not illuminate.
Different colours on Power LED.
A Red Power LED indicates multicast mode
and a Green Power LED indicates Unicast mode.
If the Tx’s power LED is green but the Rx’s is Red. Press
and hold the Rx’s ID key for 10 seconds to change to
Unicast mode. In similar scenarios hold the ID button
down on the appropriate unit to set it to the required
broadcast mode. To change both units from one broad-
cast mode to the other carry out the procedure on both.