Sample type: Defines the sampling method for the selected variable and comparing the value against the
thresholds. The possible field values are:
Delta value Subtracts the last sampled value from the current value. The difference in the values
is compared to the threshold.
Absolute value Compares the values directly with the thresholds at the end of the sampling
interval.
Falling Threshold (0 ~ 2^31-1): Displays the falling counter value that triggers the falling threshold alarm.
Falling Event Index (1 ~ 65535): Displays the event that triggers the specific alarm. The possible field
values are user defined RMON events.
Click Add to make the configurations take effects.
SNMP > RMON > RMON Event
The RMON Event page contains fields for defining, modifying and viewing RMON events statistics.
Figure 5.115 - SNMP > RMON > RMON Event Settings
The RMON Events Page contains the following fields:
Index (1~ 65535): Displays the event.
Description: Specifies the user-defined event description.
Type: Specifies the event type. The possible values are:
None Indicates that no event occurred.
Log Indicates that the event is a log entry.
SNMP Trap Indicates that the event is a trap.
Log and Trap Indicates that the event is both a log entry and a trap.
Community: Specifies the community to which the event belongs.
Owner: Specifies the time that the event occurred.
Click Add to add a new RMON event.
Monitoring > Port Statistics
The Port Statistics screen displays the status of each port packet count.
Figure 5.116Monitoring > Port Statistics