Installtion Manual

15English
Installation Requirements
Cabinet Dimensions
Maintain all max/min dimensions and clearances in the diagrams below for safe use.
CUTOUT DIMENSIONS
Range Model A B C
DOP36M86D*
42” (106.7 cm)*; 36” (91.4 cm)** 36” (91.4 cm)**; 36 1/8” (91.7 cm)*** 33 1/2” (84.8 cm)
DOP48M86D*
54” (137.2 cm)*; 48” (121.9 cm)** 48” (121.9 cm)**; 48 1/8” (122.2 cm)*** 43 1/2” (110.5 cm)
*Recommended, **Minimum, ***Maximum
1. Vertical from range grate level to combustible overhead surface; if installing an overhead hood, see hood

2. Cabinet/countertop depth is at the customer's discretion, but cabinet face must not protrude beyond the
rear of the front panel. (See Product Dimensions, Pg. 14.)
3. Consult local codes for exact location requirements.
4. Vertical from grate level to combustible surface.
5. Does not apply to cabinets more than a horizontal distance of 10" (25.4 cm) from the range edge.