Refrigerator Installation Instructions

3
Ca b i n e T la y o u T
◊ Agroundedthreeprongnon-GFCIelectricaloutletmust
be provided and should be in a location that allows the
refrigerator to be connected without an extension cord. See
“Electrical Requirements” for additional information.
◊ Theplumbingforthewaterlinecancomethroughthefloor
flush to or from the back wall. Install the water valve in a
location that allows it to be turned off without moving the
refrigerator out in the event the refrigerator or water line
requires service.
◊ FormodelIF36,seedocument100504forinstructionson
planning and installing integrated front panels. It is available
at www.Dacor.com.
WATER VALVE LOCATION -
APPROXIMATE DIMENSIONS
Wa t e r Su p p l y re q u i r e m e n t S
◊ Allinstallationsmustmeetlocalplumbingcode
requirements.
◊ Use1/4”(6mm)copperlinetoconnecttherefrigeratorto
the house cold fresh water supply.
◊ Installashutoffvalvebetweentherefrigeratorandwater
supply. The shut off valve should be a drilled saddle valve.
See the diagram above for recommended location.
◊ Donotuseapiecingtypeor3/16”(4.76mm)saddlevalve
which will reduce water flow and clog more easily.
◊ Allowaminimumof24”(610mm)diameterserviceloopof
copper tubing outside the wall or floor for easy connection to
the water supply.
Cold water supply
Connect the ice maker to a cold water line with water pressure
between 35 and 120 psi. If you have any questions about your
water pressure, call your utility company.
in s T a l l a T i o n sP e C i f i C a T i o n s
70 ½” Min.
(1791 mm)
30”.
(762 mm)
Water Valve Location - Approximate Dimensions
24” (610 mm)
36” Min. (914 mm)
16”
(406 mm)
Reverse osmosis water supply
IMPORTANT: The pressure of the water supply coming out of
a reverse osmosis system going to the water inlet valve of the
refrigerator needs to be between 35 and 120 psi (241 and 827
kPa).
If a reverse osmosis water filtration system is connected to your
cold water supply, the water pressure to the reverse osmosis
system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
If the water pressure to the reverse osmosis system is less than
40 to 60 psi (276 to 414 kPa):
■ Checktoseewhetherthesedimentfilterinthereverse
osmosis system is blocked. Replace the filter if necessary.
■ Allowthestoragetankonthereverseosmosissystemto
refill after heavy usage.
■ Ifyourrefrigeratorhasawaterfilter,itmayfurtherreduce
the water pressure when used in conjunction with a reverse
osmosis system. Remove the water filter. See “Water
Filtration System.”
If you have questions about your water pressure, call a licensed,
qualified plumber.
el e C T R i C a l Re q u i R e m e n T s
A115Volt,60Hz.AConly15or20ampfused,grounded
electrical supply is required. It is recommended that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an extension
cord.
ELECTRICAL LOCATION - APPROXIMATE DIMENSIONS
12” (305 mm)
12”
(305 mm)