Installation Instructions

5
Cabinet and Countertop Layout
WARNING
To reduce risk of burn injury from reaching over a hot appliance, do not
hang cabinets above the cooktop.
Failure to meet or exceed the max/min dimensions and clearances in
this manual may cause a fire hazard.
Follow the countertop manufacturer’s instructions regarding minimum
corner radius, use of heat-reflective tape, corner reinforcement, etc.
Carefully check the cooktop location site. For best perfor-
mance, the cooktop should be near drafts from open doors/
windows, and heating/air-conditioning vents.
This appliance is to be used with a suitable vent hood or
approved Dacor downdraft vent.
Minimum Clearances Around the Cooktop
This section consists of illustrations/notes/tables for clearance
allowances. All tolerances: +1/16” -0” unless otherwise noted.
13” max.
3
(33.0 cm)
3
This specification does not apply for cabinets located
greater than a horizontal distance of
5 1/2” (14.0 cm) from
edge of cooktop. Allow 6 7/8” (17.5 cm)
from cutout edge.
A
1 5/8” min.
(4.1 cm)
Combustible
surface to rear
30” min.
1, 2
(76.2 cm)
See cutout
dimensions
See cutout
dimensions
2
If installing with an overhead range hood, check the hood
specifications for minimum required clearances.
1
Distance to combustible surfaces measured from cooking
surface (top of cooktop grate).
18” min.
1, 3
(45.7 cm)
Model (A) Minimum (A) Recommended
HCT305G 30” (76.2 cm) 36” (91.4 cm)
HCT365G 36” (91.4 cm) 42” (106.7 cm)
1/4” (6 mm)
mimimum clearance
to combustible
surfaces
B
* Allows for clearance between hold down brackets
Allow at least ¼” (6 mm) clearance from the bottom of the
cooktop chassis to all combustible surfaces (incl. the top edge
of a drawer).
Under-Cabinet Clearances
Model (B) Minimum
HCT305G 29 1/4” (74.3 cm)
HCT365G 35 1/4” (89.5 cm)
The gas-supply piping, gas shut-off valve, and the electrical
outlet must be located so as not to impede cooktop installa-
tion. If installing an appliance below the cooktop, allow for
gas/electrical routing behind it.
Installation must allow:
access to the gas shut-off valve and regulator
access to the electrical outlet; the 42” (106.7 cm) power cord
must be able to reach its intended outlet.
access to the cooktop bottom for service/inspection.
space in the cabinet for the cooktop hold-down brackets.
Do not install a fixed shelf below the cooktop.
Downdraft Compatibility
If installing the cooktop with a downdraft, use only the approved
Dacor downdraft model numbers below.
Cooktop Model Approved Downdraft
HCT305G ERV3015
HCT365G ERV3615
Installation Specifications