Installation Instructions Renaissance ® Series Gas Cooktop Models RNCT305G, RNCT365G Part No. 109386 Rev.
Table of Contents Important Safety Instructions.......................................1 Downdraft Compatibility................................................6 Important Information About Safety Instructions...........1 Verifying the Package Contents....................................8 General Safety Precautions..........................................2 Installing the Cooktop....................................................8 Electrical Requirements................................................
Important Safety Instructions Important Information About Safety Instructions The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. • • Always contact the Dacor Customer Service Team about problems and conditions that you don’t understand. See Customer Service Information.
Important Safety Instructions General Safety Precautions To reduce the risk of fire, electric shock, or serious injury or death when using your appliance, follow basic safety precautions, including the following: WARNING • Read the accompanying use and care manual completely before operating this appliance. • Keep packaging materials away from children. Plastic sheets and bags can cause suffocation. • If you receive a damaged product, immediately contact your dealer or builder.
Important Safety Instructions Electrical Requirements WARNING To prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner’s responsibility to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed by a licensed electrician. • • The cooktop is supplied with a factory installed, 40-inch, three-prong, grounding electrical cord.
Installation Specifications Product Dimensions WARNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. All tolerances: ±1/16” (±1.6 mm) unless otherwise noted. Front of unit 1/2” male NPT gas inlet Power cord 42” (106.7 cm) long RNCT305G and RNCT365G Utility Locations Front of cooktop Power cord 1/2” male NPT gas inlet* 1 3/4” (4.4 cm) Chassis 1 3/4” (4.4 cm) 2” (5.
Installation Specifications Product Dimensions All tolerances ±1/16” (±1.6 mm) unless otherwise noted. A 2" (5.1 cm) from countertop to cooking surface 4" (10.2 cm) chassis height 21" (53.3 cm) RNCT305G and RNCT365G W x H x D Dimensions Model Rear overhang 1 3/16” (3.0 cm) Front overhang 17/32” (1.3 cm) A (width) B (width) RNCT305G 30” (76.2 cm) 27 5/16” (69.4 cm) RNCT365G 36” (91.4 cm) 33 5/16” (84.6 cm) 1 11/32” (3.4 cm) A 19 9/32” (49.0 cm) B Side View Front View 1 11/32” (3.
Installation Specifications Cabinet and Countertop Layout WARNING • To reduce the risk of personal injury caused by reaching over a hot appliance, avoid locating cabinet storage space directly above the cooktop. • Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard. • Follow the countertop manufacturer’s instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc.
Installation Specifications Cutout Dimensions All tolerances +1/16” -0” (+1.6 mm) unless otherwise noted. Countertop Cutout View Rear wall Vertical combustible surface 4 1/4” (10.8 cm) min. from mounting surface to combustibles below cooktop chassis C F E D F Countertop Cutout Dimensions Minimum distance to combustible side wall above countertop (both sides) 1 5/8” min. (4.
Installation Instructions Verifying the Package Contents • Hold-down brackets (2) • Grates: (3) • Burner sets: (5) • Gas pressure regulator: (1) • Stainless steel cleaner: (1) (stainless steel models only) Connecting the Gas Line WARNING If any parts are missing, please refer to the Customer Service Information section on the inside cover. Installing the Cooktop WARNING • Verify that the power supply meets the specifications on page 3 before proceeding.
Installation Instructions Assembling the Burners WARNING • Never attempt to operate the cooktop with any of the burner parts removed. • Do not attempt to adjust the burner air mixture settings. All adjustments are preset at the factory. 1. Remove the burner heads, burner rings, burner caps, and grates from their shipping packages. Inner burner cap (bottom shown) 2. Assemble the burners as shown below. When assembling the burner components: • match the sizes of components together, i.e.
Installation Instructions IMPORTANT: Assemble the grates as instructed below. When installed correctly, the openings in the grates are centered over the burners. 1. Locate the notch on the bottom of each grate. 2. Use the notch on the bottom of each grate to determine where the grate is placed and orientated. • The notches underneath the grates fit in the back of the cooktop. • The notches on the left and right grates fit in the sides of the cooktop. 3.
Installation Instructions Verifying the Correct Setup WARNING • Make sure that power to the electrical outlet is turned off at the circuit breaker panel or fuse box and that the gas is turned off at the gas supply valve before proceeding. • The cooktop must be properly grounded at all times when electrical power is applied. Prior to using the cooktop, read the accompanying Use and Care Manual carefully. 1. Make sure all the cooktop burner controls are in the OFF position. 2.
Installation Instructions Installation Checklist WARNING To ensure a safe and proper installation, the following checklist should be completed by the installer to ensure that no part of the installation has been overlooked. Proper installation is the responsibility of the homeowner. The importance of proper installation of your Dacor cooktop cannot be overemphasized.
Wiring Diagrams WARNING Verify that the unit is working correctly after servicing. Label all wires prior to disconnection when servicing controls. Miswiring can cause malfunction and dangerous operation. 120 Vac, 60 Hz.
Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.