Installation Instructions Distinctive ® Gas Cooktop Models DTCT304G, DTCT365G, DTCT466G, HPCT466GB, HPCT466GS Part No. 108856 Rev.
Table of Contents Important Safety Instructions........................................... 1 Important Information About Safety Instructions............... 1 General Safety Precautions.............................................. 2 Installation Specifications................................................. 3 Product Dimensions.......................................................... 3 Electrical Requirements.................................................... 4 Gas-Supply Requirements....................
Important Safety Instructions Important Information About Safety Instructions The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. Always contact the Dacor Customer Service Team about problems and conditions that you don’t understand. See Customer Service Information.
Important Safety Instructions General Safety Precautions To reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safety precautions, including the following: WARNING WARNING • Read the accompanying use and care manual completely before operating this appliance. • Keep packaging materials away from children. Plastic sheets and bags can cause suffocation. • If you receive a damaged product, immediately contact your dealer/builder.
Installation Specifications Product Dimensions All tolerances: ±1/16” unless otherwise noted. 1 5/8 in (4.1 cm) bottom of base to cooking surface 30 in (76.2 cm) Model DTCT304G 4 in (10.2 cm) chassis height 21 in (53.3 cm) 27 5/8 3/8 in in * 27 (69.5 (70.2 cm) cm) 19 1/2 in * (49.5 cm) * including raised embosses on sides of chassis Model DTCT365G 1 5/8 in (4.1 cm) bottom of base to cooking surface 36 in (91.4 cm) 4 in (10.2 cm) chassis height 21 in (53.3 cm) 19 1/2 in * (49.
Installation Specifications Electrical Requirements Gas-Supply Requirements WARNING To prevent an electric-shock hazard, the power supply must meet the specifications below. The owner shall ensure that the electrical service meets electrical requirements and that the electrical outlet is properly installed by a licensed electrician. • A factory-installed 40-in. 3-prong grounding electrical plug is connected to the chassis’s bottom right rear corner.
Installation Specifications Cabinet/Countertop Layout WARNING Under-Chassis Clearance/Allowances Allow at least 1/4” (6 mm) between the chassis bottom and all combustible surfaces (incl. edges/corners of drawers below the cooktop). • To reduce the risk of burn injury, avoid installing cabinets above the cooktop. • Not meeting or exceeding the maximum and minimum dimensions/clearances in these instructions may result in a fire hazard.
Installation Specifications Countertop Cutout Dimensions All tolerances: +1/16” -0” unless otherwise noted. IMPORTANT: Choose the correct cutout style (square or notched) on Pg. 7. Use the table below to determine the countertop cutout type and dimensions for the installation. 1. Using the Configuration and Cutout Type columns, match your DTCT model-configuration to the cutout type. 2. Double check all dimensions against the table below and the correct diagram before cutting the countertop.
Installation Specifications All tolerances: +1/16” -0” unless otherwise noted.
Installation Specifications Cutout Dimensions With ERV or PRV Series Downdraft (side view) All tolerances +1/16” -0”, unless otherwise noted. 3/8 in min. (1.0 cm) required behind cutout for downdraft cap clearance Stiffener Countertop DTCT Series Cooktop or HPCT Series Cooktop Cabinet face 3/8 in min. (1.0 cm) behind downdraft chassis to clear stiffener ERV or PRV Series Downdraft: Check downdraft specifications to determine correct fit Floor 5/8 in min. (1.
Installation Instructions Verifying Package Contents • Hold-down brackets (2) • Gas pressure regulator (1) • Grates: DTCT304G (2), DTCT365G (3) DTCT466G or HPCT466G (3) • Burners: DTCT304G (4), DTCT365G (5), DTCT466G or HPCT466G (6) • Stainless steel cleaner (1) If parts are missing, see the Replacement Parts (Pg. 12) for ordering information. Installing the Cooktop WARNING • Before proceeding, verify that the power supply meets the specifications on Page 4.
Installation Instructions Installing the Burner Assemblies Verifying the Correct Setup WARNING • Never use the cooktop if any burner parts are removed. • The burners’ air-mixture settings. 1. Remove the burner heads, burner rings, burner caps, and grates from their shipping packages. WARNING • Before proceeding, ensure power to the electrical outlet is turned off at the circuit-breaker panel or fuse box and the gas is turned off at the gas-supply valve.
Installation Instructions Proper Flame Appearance • When the unit is installed correctly, the flame burns steadily and has a sharp, blue inner cone, the length of which varies with the burner size. Installation Checklist WARNING • The installer should complete this checklist to ensure safe, thorough installation • The homeowner is responsible for the cooktop’s proper installation, the importance of which cannot be overstated.
Replacement Parts Ordering Parts DTCT466G, HPCT466GS/GB Replacement parts can be easily obtained by contacting Dacor Customer Assurance: Part Name Phone: 833-35-ELITE (833-353-5483) USA, Canada Mon – Fri, 5:00 a.m. to 5:00 p.m.
Wiring Diagrams 120V, 60Hz POWER SUPPLY AFTER SERVICING VERIFY PROPER OPERATION WIRING DIAGRAM DTCT304G CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
Wiring Diagrams 120V, 60Hz POWER SUPPLY AFTER SERVICING VERIFY PROPER OPERATION 14 WIRING DIAGRAM DTCT365G CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
Wiring Diagrams 120V, 60Hz POWER SUPPLY AFTER SERVICING VERIFY PROPER OPERATION WIRING DIAGRAM DTCT466G, HPCT466G DTCT466G CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
Notes 16
Notes 17
Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.