Installation Instructions

6
GRN
L1
BLU
BLK
GND
N1
Install the duct work according to the installation 13.
instructions for the hood or raised vent. Support the
duct weight as necessary to ensure properly sealed
joints.
Verifying Proper Operation
WARNING
Read the raised vent or hood use and care manual
completely before operation.
Test the blower operation according to the Verify Proper
Operation section of the hood or raised vent installation
instructions.
If the blower does not work, check all input and output 1.
power connections at the hood or raised vent.
Check the blower power terminal connections.2.
If the installation still does not work, contact Dacor
Distinctive Service at (877) 337-3226. Do not attempt to
repair the blower, hood or raised vent yourself. Be sure to
have all model and serial numbers from the product data
labels available when you call.
Dacor is not responsible for the cost of correcting problems
caused by a faulty installation.
Electrical Installation (continued)
Strip the three conduit wires. 6.
Connect the white (neutral) wire from the conduit to 7.
the N1 blower power terminal (see Figure 1). Tighten
the terminal screw firmly into place. IMPORTANT: The
neutral terminal on the blower has the BLACK wire
from the blower motor connected to it.
Connect the black (L1) wire from the conduit to the 8.
L1 blower power terminal (see Figure 1). Tighten the
terminal screw firmly into place. IMPORTANT: The L1
(hot) terminal on the blower has the BLUE wire from
the blower motor connected to it.
Connect the green (GND) wire from the conduit to the 9.
GND blower power terminal (see Figure 1). Tighten the
terminal screw firmly into place.
Check the wires from the blower motor to make sure 10.
that they are firmly attached to the terminal according
to Figure 2 below. Reconnect any wires that are loose.
Make sure all terminal screws are tight. Also make sure
the nut on the ground lug is tight.
Replace the blower electrical access panel.11.
Secure the other end of the conduit to the hood or 12.
raised vent and connect the wires according to the
hood or raised vent installation instructions.
Installation Instructions
Ground
lug
Figure 1:
Conduit Wire Connection
L1N1
Not
Used
Wires from
blower motor
Wires from
conduit
Black
Black
Yellow
Blue
Green
White
Green
Figure 2:
Final Blower Wiring Diagram
Wires from
blower motor
Wires from
conduit
Black
Black
Yellow
Blue
Green
White
Green