Downdraft Planning Guide

All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER,
PRV30, PRV36, PRV48
Renaissance
Slim Chassis
Downdraft Vents
Document # PG08-001
Revised 02/28/14 Page 4/7
REMP series
remote blower
3 ¼ x 10 to
round transition
and 45°
adjustable elbow
Duct work between
downdraft and
remote blower
Wall board
Cooktop
Backsplash
Downdraft vent
Downdraft vent
configured for
rear exhaust
Floor
Wiring/conduit
from downdraft
to remote blower
Cabinet blower,
option on
ERV3015 and
ERV3615
only
Cooktop
Floor
12” min.
(30.5 cm)
3 1/4 x 10
90° elbow
Wall
Downdraft vent
Wall cap
Backsplash
ILHSF series
in-line blower
3 ¼ x 10 to
round transition
Duct work Duct work
Outside wall
Range
Wall cap on
outside wall
Downdraft vent
Downdraft vent
configured for
bottom exhaust
Floor
Wiring/conduit
from downdraft to
in-line blower
Cabinet back
EXAMPLE OF LAYOUT WITH CABINET
BLOWER CONFIGURATION, EXHAUST THROUGH WALL
Duct System Layouts and Approved Blowers
EXAMPLE OF LAYOUT WITH COOKTOP
AND REAR EXHAUST
EXAMPLE OF LAYOUT WITH RANGE
AND BOTTOM EXHAUST
IMPORTANT: Do not install more than one blower with this appliance.
APPROVED DACOR BLOWERS
Blower Model Blower Rating Compatible with
CABP3
1
600 CFM
2
ERV3015
3
, ERV3615
3
ILHSF8 600 CFM
2
All Dacor ERV, PRV Series Models
ILHSF10 1100 CFM
2
All Dacor ERV, PRV Series Models
REMP3 600 CFM
2
All Dacor ERV, PRV Series Models
REMP16 1000 CFM
2
All Dacor ERV, PRV Series Models
1
IMPORTANT: Due to a lack of clearance, do not use a CABP3 blower if a
range or wall oven is to be installed in front of the downdraft vent.
2
Nominal rating at zero inches static pressure, see the blower panning
guide page for actual blower ratings.
3
Revision B and later units only. Installation of blower model CABP3
requires Dacor adapter kit # AERVCAB.
The CABP3 blower assembly is mounted to the front of the downdraft
vent with the exhaust pointing in the desired direction.
With ILHSF and REMP blowers, the downdraft vent can be configured
to exhaust through the back, the bottom or either side by removing
the appropriate exhaust knock-out.
See the following pages for duct layout requirements and maximum
duct length.