S/M No. : Service Manual Washing Machine Model: KUF-320LD ✔ Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr). Oct.
WASHING MACHINE SERVICE MANUAL 1. Overview of washing machine...................................................... 1 . . . 1. Product features (KUF-320LD).................................................................................. 1 2. Comparison of product specifications........................................................................ 2 3. Names and functions of each part............................................................................. 3 . 4. Description of the control panel...
1. Overview of the washing machine 1. Product features (KUF-320LD) ◈ New style design ◈ Sanitary washing with air bubbles and nano-silver ◈ 99.
2. Comparison of product specifications No Items KUF-320LD 1 Rated power consumption 550W 2 Wash/Spin capacity 15 Kg 3 Weight (Kg) 4 Exterior dimension (W x H x D) Net Gross 60.5 Kg 65.
3.
4. Description of the control panel Water level Reservation Depending on the laundry type, select one from hot, lukewarm or cold water. Use it to make a reservation. You can reserve it from 2 to 48 hours in advance. Water level Wind dry Select the desired amount of water depending on the amount of laundry. Used to reduce drying time after spin dry. Child protection function Use it for the swelling function. washing Use it to clean the tub.
2. Washing courses and their controls 1. Fuzzy course • Used for a general type of laundry. • Artificial intelligence will determine the water level, the washing time, the rinsing count and the spin drying time depending on the amount of laundry. 2. Eco course • Economical course to save time and water. Course Select saving. Course Select saving. Course Select saving. 3. Wool course Course Select saving. • Used to wash sweaters, lingerie or stockings.
3. Air bubble up washing and button controls ■ Reservation washing • Wool or washing tank cleaning can’t be reserved. Drying time 10, 20, 30 or 40 minutes Select a Set the desirable course. reservation time. ■ Wind dry • Use a small amount of laundry. • The Wind dry also removes moisture. It can reduce the drying time. Drying time 10, 20, 30 or 40 minutes Select a Set the desirable course. reservation time.
4. Parts list by ass'y 1.
2.
No.
■ CABINET ASS'Y (KUF-320LD) 09 10
No. Part Name Q'ty Remarks PRCACAZJ10 DWF-320LKTC 1 ASSY PART B01-1 CABINET 361081W800 SGCC 0.8T , BLACK, DWF-320LKTC 1 B01-2 PLATE-UPPER 3614541300 SGCC 0.8T 1 B01-3 PLATE-LOWER 3614541400 SGCC 0.8T 1 B01-4 SUPP TUB FL 3615305300 SGCC 2.0T 1 B01-5 SUPP TUB FR 3615305400 SGCC 2.0T 1 B01-6 SUPP TUB BL 3615305500 SGCC 2.0T 1 B01-7 SUPP TUB BR 3615305600 SGCC 2.
■ TUB ASS'Y (KUF-320LD) T22 T21 T18 T20 T19 T16 T17 T09 T11 T10 T13 T12 T14 T15 T23 T03 T01 T07 T07 T02 T04 T06 T08 12
No. T01 Part Name Part Code Specifications Q'ty TUB O 3618830300 FRPP, DWF-320 1 - HOSE OVERFLOW 3613208901 PELD L=280mm 1 T02 CLUTCH DRAIN AS 3615418600 DWF-320LPSP 1 T03 SUSPENSION AS 36100T1J00 DWF-320, VP TYPE, SPRING 10 1/2 TURN WH 4 T04 DRAIN MOTOR 36196TAX00 SV-HJ7T24D, 100-110 50/60HZ 1 - SCREW TAPPING 3616007001 SCM24H, 6.
3. Disassembly procedure (KUF-320LD) 1. Front panel disassembly procedure (KUF-320LD) 1. P ull out the detergent box 2. Remove the set screws from Panel F ➡ 3. P ush the front panel to the left and separate the clamping hook 4. Remove the set screws for the PCB assembly and separate the PCB assembly. ➡ 2. Rear panel disassembly procedure (KUF-320LD) 1. Remove the rear panel set screws. 2. Lift up and separate the rear panel.
5. Circuits 1. Sequence chart ■ SEQUENCE CHART(KUF-320LD) FUZZY Classification Time Sensing W A S H Water supply 4min. Soak 30min. Mid. spin Medium /High High ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ 17min. 11min. 13min. 15min. 15min. ▒ ▒ ▒ ▒ ▒ ▒ ▒ 6min. ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ 2min. ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ 5min. ▒ ▒ ▒ ▒ ▒ ▒ 4min. ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ Water supply 4min. ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒ Rinse 1 3min.
■ SEQUENCE CHART2 (KUF-320LD) Classification W A S H Sensing Water supply Soak Drain Balancing spin Mid. spin Water supply Rinse 1 Drain Balancing spin R I N S E Mid. spin Water supply Rinse 2 Drain Balancing spin Mid. spin Water supply Rinse 3 Drain Balancing spin S P I N Time 4min. 30min. 20min. 15min 10min. 2min. 5min. 4min. 4min. 3min. 2min. 2min. 5min. 4min. 4min. 3min. 2min. 2min. 5min. 4min. 4min. 3min. 2min. 2min. 9min.(12min.) 7min.(10min.) 5min.(8min.) Main spin 3min.(6min.) 1min. (4min.
2. Operation for each button Button Operation Power 1. M icro switch type is used to meet the 0.5W of standby power consumption requirement. • Tact switch type is used for other regions that do not have 0.5W requirement. (D16 setting of F-PCB; D16 connected ➔ Tact SW, D16 disconnected ➔ Encoder SW) 2. When the “Power” button is pressed, the power supply relay is engaged and “---” will be shown on the display. 3. All other LEDs are off. 4. Automatic power off function: 5.
Button Operation Soak 1. S oak time can be selected for all courses except the Wool course 2. Soak time is set to 120 minutes for Tub Clean course and 30 minutes for all other courses. 3. If the Soak button is pressed before washing, the default wash time for each course will be selected automatically. Wash 1. W ash time can be set from 0 min to 120 min in one minute step. 2. The washing time will be incremented every 0.3 seconds while pressing this button.
Button Air wash Operation 1. T he sequence of selection is 10 min ➔ 20 min ➔ 30 min ➔ 40 min ➔ 50 min ➔ 60 min ➔ 0. (5 min of balance spin time will be added in certain period of time after the selection by button.) 2. Air wash time is incremented by 10 min while pressing the button. When the button is released, the selected air wash time blinks for three seconds and total course time will be shown on the display. 3. This cannot be selected for the Wool, Underwear, and Tub Clean courses. 1.
3. Error displays and causes of errors Error display Details • This error occurs when the water level sensor frequency is over 30 KHz or below 15 KHz and also when the frequency is increased suddenly by more than 1.44 KHz in four seconds after filling up water. ➔ Water level sensor hose is off the position.
■ Errors related to the motor Error display Details E5 High voltage error E6 IPM Fault error E7 Motor hall sensor error E8 Motor operation overloading error This error occurs when there is no next hall sensor input within 320 msec due to overloading of the motor. b1 Motor alignment error This error occurs when the alignment of the motor at the initial stage of motor operation is against the logic.
4. Various test modes 4-1. Electronic device operation test mode 1) Procedure to enter the test mode - Press the Wash button three times while pressing the Water+ (water level) button in the initial state. 2) Operation procedure - Use the Soak button to test various devices. No.
4-2. Spin discharge test mode 1) How to enter - In the initial condition, press the rinsing button three times while holding down the water level button. 2) Control procedures - Using the spin dry button select the target RPM. (300 ~ 800RPM: steps of 20RPM) - Press the start/pause button to start spin drying. 3) The current RPM is displayed during operation. When it stops the target RPM is displayed. 4-3.
5. Troubleshooting Symptom Items to check Resolution • Check the power supply voltage • Check the power loss or circuit breaker Check the power supply Washing machine is not turned on. Check whether the fuse is blown ➡ • Replace the fuse and check the operation in the test mode to see whether the fuse is blown again • If the fuse is blown during water filling, measure the resistance of water supply valve and replace it if it is shorted.
Symptom Tub turning during washing Items to check Resolution • Remove any alien substances between the lever clutch and the link valve drain. Open the door and check if the tub is rotating. • Disassemble the rotor and check the clutch and any damage in the coupling. • Replace the spring lift. Water is continuously filled up even when the machine is turned off. Water supply is not turned off Water draining does not work After reaching the HIGH level, water supply continues.
Symptom Lamp is not turned on. Items to check Resolution • Check the failure of the lamp. • Replace the lamp • Check the contact status of connector and terminals • Replace the PCB. Check the levelness of the set. • Adjust the levelness. Check deformation of the safety lever. • Replace the safety lever. Check if the sync motor wire is tight. • Replace the sync motor. Check for alien substances in the discharge valve bellows. • Remove alien substances.
DAEWOO ELECTRONICS CORP. 686, AHYEON-DONG MAPO-GU SEOUL, KOREA C.P.O. BOX 8003 SEOUL, KOREA TELEX: DWELEC K28177-8 cable: “daewooelec” S/M No. : PRINTED DATE: Oct.
ABOUT THIS MANUAL VISION CREATIVE. INC. 서울 종로구 통의동 6번지 이룸빌딩 4층 담 당 박준영 님 (서비스메뉴얼) F.MODEL B.