Service Manual Full-Auto Electric Washing Machine DWF-4220 (Series) DWF-5020 (Series) DAEWOO ELECTRONICS CO., LTD. 612-1, AHYEON-DONG, MAPO-GU, SEOUL, KOREA. C.P.O. BOX 8003 SEOUL KOREA TELEX: DWELEC K28177-8 CABLE:"DAEWOOELEC" FAX: (02) 364-5588/5305 TEL: (02) 360/7315~7 S/M NO.: WF42200100 PRINTED DATE: APR. 1996 DAEWOO ELECTRONICS CO., LTD.
TABLE OF CONTENTS 1. SPECIFICATIONS.................................................................................................................................................................... 2 2. FEATURE AND TECHNICAL EXPLANATION FEATURE OF THE WASHING MACHINE ............................................................................................................................... 3 WATER CURRENTS TO ADJUST THE UNBALANCED LOAD ...................................................................
1. SPECIFICATIONS NO ITEM AC 220V/60Hz AC 127V/50,60Hz AC 110V/60Hz AC 220V/50Hz AC 240V/50Hz DWF-4220 370W 370W 370W 330W 330W CONSUMPTION DWF-5020 430W 430W 430W 370W 370W MACHINE DWF-4220 NON PUMP: NET; 30.5kg, GROSS: 35 kg PUMP: NET; 31.5kg, GROSS; 36kg WEIGHT DWF-5020 PUMP: NET; 32.5kg, GROSS; 37kg 1 POWER SOURCE 2 POWER 3 SPECIFICATIONS NON PUMP: NET; 31.
2. FEATURE AND TECHNICAL EXPLANATION FEATURE OF THE WASHING MACHINE 1) The first air bubble washing system in the world. 2) Quiet washing through the innovational low-noise design. 3) The wash effectiveness is much more enhanced because of the air bubble washing system. 4) The laundry detergent dissolves well in water because of the air bubble washing system. 5) The adoption of the water currents to adjust the unbalanced load. 6) One-touch operation system.
PULSATOR SYSTEM When the new shaped pulsator is rotated C.W or C.C.W at a high speed, it makes the 'heart-shaped' water currents as shown below. C WATER CURRENTS A Water is pushed up near the tub wall by rotation of the pulsator. Rotate B Water is pulled down in the middle of the tub by rotation of the pulsator B A C Water currents is generated by rotation of the pulsator. A AUTOMATIC DRAINING TIME ADJUSTMENT This system adjusts the draining time automatically according to the draining condition.
SOFTENER DISPENSER This is the device to dispense the softener automatically by centrifugal force. This is installed inside the Balancer Ass'y. FUNCTIONAL PRINCIPLE 1. Softener stays in room (A) when poured into softener inlet. 2. Softener in moved from (A) to (B) by centrifugal force during intermittent spin process. 3. Softener flows from (B) to (C) during rinse process next to intermittent spin. 4. Softener in moved from (C) to (D) by centrifugal force during second intermittent spin.
AUTOMATIC UNBALANCE ADJUSTMENT This system is to prevent abnormal vibration during intermittent spin and spin process. FUNCTIONAL PRINCIPLE 1. When the door is closed, the safety switch contact is "ON" position. 2. In case that wash loads get uneven during spin, the outer tub hits the safety switch due to the serious vibration, and the spin process is interrupted. 3. In case that P.C.B. ASS'Y gets "OFF" signal from the safety switch, spin process are stopped and rinse process is started automatically by P.
LINT FILTER Much lint may be obtained according to the kind of clothes to be washed and some of the lint may also stick to the clothes. To minimize this possibility a lint filter is provided on the upper part of the tub to filter the wash water as it is discharged from the water channel. It is good to use the lint filter during washing. Bleach inlet Filter Pulsator HOW TO CLEAN THE LINT FILTER 1. Pull the filter frame upward. 2. Turn the lint filter inside out, and wash the lint off with water. 3.
GEAR MECHANISM ASS'Y The proper water currents is made by the rotation of pulsator at a low speed to prevent the damage to the small sized clothes. Pulsator shaft Spinner shaft One clutch bearing Planetary gear Sun gear Planetary gear Internal gear Clutch spring Brake lever Clutch boss Spinner pulley Pulsator Motor Planetary V.BELT 1 revolution Motor Spinner Pulley Planetary gear 1/5.0 Pulsator 5 revolutions Tub Spinner pulley Directly V.
PRINCIPLE OF INTAKE & OUTLET OF THE AIR INTAKE : ARMATURE moves up, and BELLOWS inhales the air. At the same time, protector B is open and A is close. OUTLET: ARMATURE moves down, and BELLOWS exhausts the air. At the same time, protector B is close and A is open. FUNCTIONAL PRINCIPLE OF TRANS & MAGNET • The phase of A.C electric power changes to 60 cycle/second. • The magnetic pole of trans core is changed by the change of the phase of A.C electric power. • The core repeats push and pull (3600 times/min.
3. STRUCTURE OF THE WASHING MACHINE • SOFTENER INLET Pour softener into the softener inlet just before wash and it will be added into the tub automatically just before the final rinse. • BLEACH INLET • POWER SWITCH • HOOK HOLE • TUB • LINT FILTER • HANDLE • GROUND WIRE • CONTROL PANEL • POWER CORD • ADJUSTABLE LEG ACCESSORIES Drain Hose Clamp Drain Hose Under Base Cover [Option] P U In case of screw-shaped inlet hoses water tap adapters will not be provided.
4. FUNCTIONS OF THE CONTROL PANEL Control Panel It has micom sensor. As the buttons are pressed, the lamps indicating the selection of your desired washing program will light up. Start/Hold Button Power Switch SP H SE IN AS R W ZZ SP Y EE H DY EA V W Y O O L FU H ED LO IUM W SM AL L IG M H M LD O C T AR O POWER W OFF • Press this switch to turn the power ON or OFF. • After turning off the power, wait for more than 3 seconds and then turn it on again.
5. DIRECTIONS FOR INSTALLATION AND USE HOW TO INSTALL THE WASHING MACHINE Selection of the Installing Place Install the washer on the horizontal solid floor. If the washer is installed on an unsuitable floor, it could make considerable noise and vibration. Never install in these places. • The place where it would be exposed to direct sunlight. • The place nearby a heater or heat appliances. • The place where it would be supposed to be frozen in winter.
¡ Installing the Drain Hose [Pump Model] Never forget to install drain hose before operating this washing machine. The packing box opened, there are a drain hose, a clamp, and a hose fixture. the hose guide, included ™ Attach in the accessory kit, to guide the drain hose over the tub or standpipe. £ Hook the drain hose to the edge of the tub, paying attention that there are no bends or constractions along the drain hose.
HOW TO CONNECT THE INLET HOSE In Installing the Inlet Hose ¡ Pull down the collar of the inlet hose to separate it from the water tap adapter. ™ Water Tap Adapter Loosen the four screw at the water tap adapter, but don't loosen the screws until they are separated from the water tap adapter.
HOW TO GROUND THE WIRE Grounding Method • If your water tap or water pipe is not made of metal, connect the ground wire to a copper plate or a metal rod and bury it in the earth. 20Cm • If both your water tap and water pipe are made of metal, connect the ground wire to the base of the water tap. • In case of using 3-core cord, there is no need for grounding. * It is of no use connecting the ground wire to the water pipe made of plastic.
W AS R H IN S SP E IN ZZ SP Y EE H DY EA V W Y O O L FU M H H O T W AR C M O LD IG H ED LO IUM W SM AL L 6. PROCEDURE OF FULL-AUTOMATIC WASHING START/HOLD WATER LEVEL WATER TEMP. COURSE PROCESS Full Automatic Course Selecting Course FU IG Lightly stained clothes: underwear, T-shirts, Y-shirts, etc..
W AS R H IN S SP E IN ZZ SP Y EE H DY EA V W Y O O L FU IG H ED LO IUM W SM AL L M H O T W AR C M O LD H START/HOLD WATER TEMP. COURSE WATER LEVEL PROCESS Partial Selections Among Wash, Rinse or Spin Selecting Water level IN SP IN SP H IN R IN R AS AS H IN S SP E IN W End of Process IN IN It is informed by buzzer.
7. DIRECTIONS FOR DISASSEMBLY AND ADJUSTMENT WARNING BEFORE ATTEMPTING TO SERVICE OR ADJUST ANY PART OF THE WASHING MACHINE, DISCONNECT THE POWER CORD FROM THE ELECTRIC OUTLET. GEAR MECHANISM ASS'Y REPLACEMENT • Raise the top plate on the outer cabinet. • Loosen four screws mounting outer tub cover and remove outer tub cover from the tub ass'y • Loosen the pulsator mounting screw and remove pulsator.
SYNCRONOUS MOTOR AND VALVE REPLACEMENT • Lay the front of the washer on the floor. • Loosen the adjustment screw and three bolts mounting the drain motor. • Take out the wire of syncronous motor from the bracket. • Separate the syncronous motor from the bracket. • Turn the valve lid by using screw driver as shown in figure and remove the valve lid from the valve frame.
8. TROUBLE SHOOTING GUIDE NOTE: 1. When you replace the P.C.B. ASS'Y do not scratch the surface of the P.C.B. ASS'Y. 2. Disconnect the power cord from the electric outlet. CONCERNING WATER SUPPLY PROBLEM CHECK POINT CAUSE Do you open the Water tap? NO SOLUTION Open the water tap. YES Is the filter of the water inlet valve clogged with dirt? YES Clean the filter. NO Is the water pressure sufficient? 2 (0.3~8 kgf/cm ) NO Increase the water pressure.
PROBLEM CHECK POINT CAUSE NO Is the plug connected to electric outlet? SOLUTION Connect the plug. YES NO Is the power switch pressed? THE INDICATOR LAMP (LED) DOES NOT LIGHT UP WHEN THE POWER S/W IS PRESSED. Press the power switch. YES Is the condition of power switch good? NO Power switch is defective. Change power switch. NO Improper connection of the connector. Connect the connector properly. NO Transformer is defective. Change the transformer. P.C.B ASS'Y is defective. Change P.C.
CONCERNING DRAINING PROBLEM CHECK POINT CAUSE YES Is the door open? SOLUTION Close the lid. NO Does the safety switch operate normally? THE WASHER DOES NOT DRAIN. NO Safety switch is defective. NO Improper connection of the connector Connect the connector properly. P.C.B ASS'Y is defective. Change P.C.B ASS'Y. Improper installation Install drain hose properly. Drain problem by the foreign matter accumulated inside drain valve housing. Remove the foreign matter. Change the safety switch.
CONCERNING SPINNING PROBLEM CHECK POINT CAUSE SOLUTION Does the pulsator rotate while the tub does not rotate? NO THE WASHER DOES NOT SPIN. YES Is the input voltage of the drain motor normal? YES NO Is the V-belt worn out? YES Syncronous motor is defective. Change the Syncronous motor. P.C. B ASS'Y is defective. Change the P.C.B ASS'Y. V-belt is defective. Change the V-belt. YES Motor is defective. Change the motor. NO Improper connection.
CONCERNING OPERATION PROBLEM CHECK POINT CAUSE NO Is the plug connected to electric outlet? SOLUTION Connect the plug. YES NO Is the power switch pressed? THE INDICATOR LAMP (LED) DOES NOT LIGHT UP WHEN THE POWER S/W IS PRESSED. Press the power switch. YES Is the condition of power switch good? NO Power switch is defective. Change power switch. NO Improper connection of the connector. Connect the connector properly. NO Transformer is defective. Change the transformer. P.C.
9. PRESENTATION OF THE P.C.B ASS'Y CONCERNING ERROR MESSAGE MESSAGE CAUSE ƒoƒoƒo DRAINAGE ERROR LEVEL SENSING ERROR ƒoƒoƒo The drain hose is blocked up by foreign matter. Remove foreign matter from drain hose. Drain motor is inferior. Change drain motor. ƒoƒoƒoƒo §§§§ §§§ The water tap is closed. Open the water tap. The water inlet filter clogged. Clean the water inlet filter. It passes over the 30 minutes, yet it doesn't come to assigned water level.
TEST MODE The operation condition of the washer can be checked without water in the tub by test mode of the P.C.B. ASS'Y as shown below. No.
CONFIGURATION OF FULL CIRCUITS LOAD DRIVE UNIT (MOTOR, WATER INLET, DRAIN, BUBBLE) WATER LEVEL SENSOR UNIT DISPLAY UNIT L.E.D M I C O M I.C LOAD SENSOR UNIT INTERRUPT UNIT D W F 4 2 2 0 POWER SUPPLY UNIT MAIN OSC (4.
MINUTE EXPLANATION DIAGRAM FOR EACH PARTS MICOM IC (42 DIP) VAREF 1 42 VDD VASS 2 41 R92(SCK) R40 (AIN0) 3 40 R91(SO) R41 (AIN1) 4 39 R90(SI) R42 (AIN2) 5 38 R83(T1) R43 (AIN3) 6 37 R82(INT1) R50 (AIN4) 7 36 R81(T2) R51 (AIN5) 8 35 R80(INT2) R52 (AIN6) 9 34 HOLD(KEO) R53 (AIN7) 10 33 RESET R60 11 32 XOUT R61 12 31 XIN R70 13 30 TEST R71 (WTO) 14 29 K03 R72 (XTIN) 15 28 K02 R73 (XTOUT) 16 27 K01 P10 17 26 K00 P11 18 25 P23 P12 19 24
LOAD DRIVE UNIT (CW WASH, CCW WASH, DRAINAGE, BUBBLE, PUMP, HOT WATER, COLD WATER) 1. CIRCUIT DIAGRAM AND EXPLANATION 1 BL/YW RA1 R1 C1 683k 100 1W R67 10K 3.3K R51 10 SM12JZ47 Q8 A1270 R21 C2 104Z 62 R1/2W R69 10K 3.3K R53 9 R2 R52 8 10K 3.3K C4 104Z R5 Q11 A1270 R19 R50 7 10K 3.3K R4 10K 3.3K R73 5 10K 3.3K 4 10K 3.3K R75 3 3.
2. DETAIL EXPLANATION OF CIRCUIT ACTION (ACTION OF CW WASH) 6V C1 683K C2 104Z 10K 10 R1 100 1W TRC1 SM12JZ47 R67 3.9K Q8 A1270Y MICOM AC COMMON +6V R21 62 1/2W •In case MICOM TERMINAL No. 10 is 'L', the Q8 (A1270Y) turn on and control the TRIAC. The resistance, as 62Ω & 1/2W, of the R21 is used to limit the GATE current of the TRIAC. •The ceramic condenser C2 between the T1 and the GATE of the TRIAC is used for preventing the wrong action by means of the noise.
• The TRIAC's names and the values of the snubber & resistance of the total parts.
2. EXPLANATION OF CIRCUIT • Push the power switch. And, in order to carry on the action of course selection, input the selection of frequency according to each water level selection. • The frequency of water level sensor in each water level becomes square wave and is sended to the MICOM. WATER LEVEL NAME FREQUENCY WATER LEVEL HIGH MIDDLE LOW SMALL 23.0 kHz 23.5 kHz 24.0 kHz 24.4 kHz 450 ± 15 380 ± 15 300 ± 15 240 ± 15 RESET 25.30 kHz OVER FLOW 22.
ELECTRIC POWER SUPPLY UNIT 1. CIRCUIT DIAGRAM D5 IN4003 42 Vdd C29 104Z C22 + 104Z 470uF – 50V 16V IC1 REGULATOR C28 7806 104Z C27 50V 104Z 50V C25 470uF 16V D3 1N4003 + C26 1000uF – 35V D2 1N4003 2. EXPLANATION OF CIRCUIT • The primary voitage of the transformer sets RATING VOLTAGE, the secondary voltage of the transformer is full wave rectified by use of the D2 (1N4003) & D3 (1N4003) $ The waveform of output in the REGULATOR I.C. 7806.
• The Electrolytic condenser C22(1000µF, 16V) and diode D5 is used in order that at instant power supply failure circuit should remember the contents of the program. It happens that the MICOM terminal No. 42 has instant interruption of electric power, yet the MICOM is not discharged electricity because of the diode D5. • The measurement of voltage EFFECTIVE VALUE ! @ # $ % 82.5V 5.2V 7.9V 7.9V 5.97V 5.4V 119V 7.2V 11V 11V 5.97V 5.4V 137.5V 9.3V 14.1V 14.1V 5.98V 5.4V 165V 5.3V 7.
• After connecting the part of the dotted line & waveform measurement • The waveform measurement in the MICOM No.37. 5.4V 0V 0V The waveform of the secondary part in transformer passes through the diode D1,D4 (1N4003), and then the voltage is divided by means of the resistance R60 & R61. This voltage gives force to input the pulse to the MICOM terminal No. 37 on the ground of action of the TR Q6 (C3202Y). 3.
BUZZER UNIT 1. CIRCUIT DIAGRAM 6V MICOM R57 220 20 BUZZER 2. EXPLANATION OF CIRCUIT • After the button action and total process ends, BUZZER is active. • It is active directly with offering an output the frequency waveform of 2 KHz from the MICOM terminal NO. 20. BUTTON INPUT UNIT 1. CIRCUIT DIAGRAM +6V 34 HOLD R53 10K R54 Q4 A1270 17 P10 3.9K R56 10K R55 Q5 A1270 18 P11 3.9K Q7 R62 10K R63 A1270 11 R60 3.
OSCILLATION UNIT 1. CIRCUIT DIAGRAM XOUT XIN 32 X1 C18 4.194304 MHz 31 33pF C17 33pF 2. EXPLANATION OF CIRCUIT • As the OSCILLATION UNIT is a basic part of the MICOM DRIVE. If the oscillation doesn’t generate, we are able to consider that the MICOM is destroyed. • The waveform between the part of ! and the GND. f = 4.194304 MHz t • Specification of oscillator It is in general use for the MICOM maker's recommendatory value of condenser which is fit for MICOM's characteristics.
2. EXPLANATION OF CIRCUIT • The MICOM terminal No. 13 gets into 'L' at the state of the closed door. If the door is opened in spining stage, the MICOM generates error signal. (See page 27) • Case of range 40 mSEC~300 mSEC in spining time: It is regarded that washing clothes should be inclined. Accordingly washing time increases 8 minutes and rinsing action takes place another one time. Case of above 400 mSEC: It is regarded that the door should be open. Therefore it is displayed as door open error.
DISPLAY UNIT 1. CIRCUIT DIAGRAM +6V 34 HOLD R53 10K R54 Q4 A1270 17 P10 3.9K R56 10K R55 Q5 A1270 18 P11 3.9K R62 10K R63 Q7 A1270 HOT HI 11 R60 3.9K STANDARD R66 220 22 P20 WARM MED SPEED R9 220 23 P21 COLD LOW DIRTY R64 220 24 P22 DHY MIN DRY/WOOL R58 220 25 P23 RINSE WASH R34 220 19 P12 • When electric power source is turned on, the LED lamp is turned on necessarily corresponding to the standard course.
EARTH 1 RD/BL RD/BL 3 2 PK WH/RD WH WH POWER SWITCH WH WH/RD WH/RD PK 7 6 5 4 HOT W/S VALVE 7 6 5 4 WH/RD LINE FILTER COLD W/S VALVE 3 YK 2 GN/YW OR GN 2 1 BL/YW BL/YW FUSE BK BR OR BK BN/YW OR GN BL OR WH YW/BK YW VT 2 2 1 9 8 1 2 DRAIN PUMP 1 2 BUBBLE WH GENERATOR PK 9 1 1 WH/RD WH/RD SYNC.
1 RD/BL RD/BL 3 2 PK WH/RD WH WH POWER SWITCH WH WH/RD PK 9 8 7 6 5 4 9 8 7 6 5 4 GN/YW OR GN 2 1 WH/RD LINE FILTER COLD W/S VALVE 3 2 YW/BK FUSE 1 VT 2 1 BL/YW BL/YW FUSE BK BR OR BK EARTH BL OR WH BL 1 BL/YW BL/YW 1 2 SYNC.
PART LIST REF No. PART CODE PART NAME DESCRIPTION Q'TY REMARK ASS'Y PLATE P01 3614511900 PLATE T HIPS 1 P02 3612723300 HARNESS AS AC 220V/50Hz, 60Hz 1 3612723310 AC 110V/50Hz, 60Hz 3612723340 AC 100V/50, 60Hz P03 3614213100 PANEL F HIPS 1 P04 3611609200 DECORATOR PC FILM 0.
REF No. PART CODE PART NAME DESCRIPTION 3616102800 BALANCER AS PP Q'TY REMARK 1 DWF-4220 ASS'Y TUB T01 3616003100 T02 3618803500 PP TUB I PP 3618805400 DWF-5020 1 YUS 430D 0.
REF No. PART CODE PART NAME DESCRIPTION T26 7640061611 BOLT HEX (to PROTECTOR) 6B-1, 6x16, SW, MFZN 2 T27 3966130120 MOTOR SYNCHRONOUS 100V/50, 60Hz (JE) 1 450ED45020 110-130V/60Hz (PT/S/A) 3966010140 220-240V/50Hz (PN/M) Q'TY T28 3615404000 VALVE DRAIN AS NON-PUMP 1 T29 3613215100 HOSE DRAIN I AS PUMP 1 3613210300 T30 T31 3610032640 NON-PUMP UNIT CAPACITOR AS 13.5µF+60µH (PL, LE) 3618909300 65µF+60µH (JE) 3610076140 54µF+60µH (PT, TE) 3610031940 12.
REF No. PART CODE PART NAME DESCRIPTION B09 3611901800 FILTER LINT P.P (5-150) 1 B10 3614002000 PACKING NBR 1 B11 3616004300 SPECIAL WASHER P.C SHEET 1 B12 3610903800 CAP FILTER P.
PARTS DIAGRAM P02 P10 P23 P20 P10 P09 P12 P22 P01 P18 P08 P11 P18 P16 P07 P15 P14 P03 P04 P13 P05 46
T05 T14 T03 T13 T12 *DWF-4220 T04 T11 T01 T10 T02 T02 T07 T32 T08 T30 T27 T06 T31 T22 T18 T15 T23 T20 T21 T16 T17 *NON-PUMP MODEL T28 T24 T19 T29 T25 T17 T26 T29 47
W01 C02 W01 C03 C04 C01 W03 B14 B13 NON-PUMP MODEL A01 B08 C05 W04 B01 A02 A01 B12 B11 B10 B09 B08 B05 B13 B02 B07 B04 B03 B06 48
P.C.B PARTS LIST REF No. PART CODE PART NAME DESCRIPTION R18 RD-4Z392JK R CARBON FILM 1/4 3.9kΩ J R26 RD-4Z392JK R CARBON FILM 1/4 3.9kΩ J R50 RD-4Z392JK R CARBON FILM 1/4 3.9kΩ J R52 RD-4Z392JK R CARBON FILM 1/4 3.9kΩ J R54 RD-4Z392JK R CARBON FILM 1/4 3.9kΩ J R55 RD-4Z392JK R CARBON FILM 1/4 3.9kΩ J R63 RD-4Z392JK R CARBON FILM 1/4 3.9kΩ J R67 RD-4Z392JK R CARBON FILM 1/4 3.9kΩ J R69 RD-4Z392JK R CARBON FILM 1/4 3.9kΩ J R70 RD-4Z392JK R CARBON FILM 1/4 3.
REF No.
REF No. PART CODE PART NAME DESCRIPTION C24 CCZF1E103Z C CERA 25V 0.01µF Z AXL 2 C2 CCKF1H104Z C CERA HIKF 50V 0.1µF Z AXL 2 C4 CCKF1H104Z C CERA HIKF 50V 0.1µF Z AXL 2 C6 CCKF1H104Z C CERA HIKF 50V 0.1µF Z AXL 2 C8 CCKF1H104Z C CERA HIKF 50V 0.1µF Z AXL 2 C10 CCKF1H104Z C CERA HIKF 50V 0.1µF Z AXL 2 C12 CCKF1H104Z C CERA HIKF 50V 0.1µF Z AXL 2 C14 CCKF1H104Z C CERA HIKF 50V 0.1µF Z AXL 2 C19 CCKF1H104Z C CERA HIKF 50V 0.
REF No.
REF No.
CIRCUIT DIAGRAM [PUMP] BL/YW RA1 Q8 A1270 10K R67 100 1W R53 10 3.9K 30 TEST +6V R52 9 R5.3 10K 10K R71 R13 330 R1/4W 3.9K 18 P11 C7 R4 3.
CIRCUIT DIAGRAM [NON-PUMP] BL/YW RA1 21 VSS Q8 A1270 10K R67 100 1W R53 10 3.9K 30 TEST +6V R52 9 R5.3 10K 10K R71 Q5 A1270 R56 10K R12 330 R1/4W 3.9K 17 P10 R13 330 R1/4W 3.9K 18 P11 C9 C7 R4 HOT HI 11 R60 R9 220 WED A6 A6 BL W/M LEFT 250VAC YW/BK A4 A4 DRAIN MOTOR YW/BK BUBBLE PUMP BCR1AM PK A2 A2 PK 1 1 TRIAC4 2 2 10K 3.9K BL/WH R73 DRAIN PUMP A8 3.
BARE PCB TOP BOTTOM 56