Installation manual

3 English
Outdoor Unit Installation Drawings
Model
Max. allowable height
Min. allowable length
Max. allowable length
30m
1.5m
20m
60 class50 class 71 class
Liquid pipe
Gas pipe
O.D. 6.4mm
O.D. 12.7mm
O.D. 15.9mm
20g/m
Additional refrigerant
required for refrigerant
pipe exceeding 10m
in length.
(Foot bolt-hole
centres)
330mm
Allow space for piping
and electrical servicing.
250mm from wall
CAUTION
Set the piping length
from 1.5m to 30m.
Wrap the insulation
pipe with the finishing
tape from bottom to top.
Stop valve cover
Service lid
Where there is a danger of
the unit falling, use foot bolts,
or wires.
In sites with poor drainage,
use block bases for outdoor
unit.
Adjust foot height until the
unit is leveled. Otherwise,
water leakage or pooling of
water may occur.
(Foot bolt-hole centres)
580mm
120mm
(From unit’s side)
01_EN_3P159684-2F.fm Page 3 Wednesday, December 7, 2005 3:18 PM