Service manual

MAN 650314:D
20
*NOTE: Selecting Celsius units will only change the reading on the LCD message centers
since the VHX needle sweeps are set for Imperial units. You will also need to enable the
message in order to display it.
When “sender” is displayed, press and hold SW1 until the message changes.
Release SW1 and the current sensor selection will be displayed.
Press and release SW1 to scroll through the sensor options DD FDD CBUS F
BUS C”.
When the desired setting is displayed, press and hold SW1 until “DONE” is displayed.
Release the switch to go on to the next sub- menu item.
Temp warning setup (Warning)
This menu will allow you to select the high temperature warning point. When the display
value is higher than this point, a high temp warning message will flash the current water temp in
the LCD1 display. The value is adjustable from 150 – 300 F (65-148 C).
When “Warning” is displayed, press and hold SW1 until the message changes.
Release SW1 and the current warning point will be displayed.
Press and release SW1 to increase the value from “HI 150F” – HI 300F”.
When the desired value is displayed, press and hold SW1 until “DONE” is displayed.
Release the switch to go on to the next sub-menu item.
Temp sensor test (test)
This menu will allow you to check the resistance the control box is reading from the water
temp sensor. This can be used for a diagnostic tool if you are having trouble or feel that the
reading is incorrect. For the Dakota Digital SEN-04-5 the resistance decreases as temperature
increases. Typical values for the Dakota Digital SEN-04-5 sensor are:
100F - 500 ohms
200F - 75 ohms
300F - 19 ohms
If the message display is showing “EEE” this is an open connection or no sensor connected. If it
is reading “ ---” this is indication of a short.
When “water test” is displayed, press and hold SW1 until the message screen
changes.
Release SW1 and the current resistance from the fuel level sensor will be displayed as
test temp” “xxx ohms” where xxx is the resistance seen at the control box.
Press and release SW1 to scroll to other sensor inputs if you wish “oilFueltemp”.
Once complete, hold SW1 until “DONE” is displayed.
Release the switch to go on to the next sub-menu item.
Exit water temp setup (done)
This will allow you to exit the water temp setup and go on to the next setup menu.
When “water done” is displayed, press and hold SW1 until you get “DONE”.
Release the switch to go onto the next menu.