Installation Manual

MAN 650314:J
22
Exit oil pressure setup (done)
This will allow you to exit the oil pressure setup and go on to the next setup menu.
When “oil done” is displayed, press and hold SW1 until you get DONE
Release the switch to go on to the next menu
FUEL SETUP
The control box can read eight common fuel level sender resistance values. If your sender
is not shown in the table below, the system can be programmed to read a custom sender. If
BUS” is selected for the sender type, the fuel level should be coming into the AUX I/O port
through the use of a BIM module. The table below shows the eight pre-programmed senders and
their respective empty and full resistance values.
Sender type
Menu
Empty R
Full R
GM 0-30 ohm(mid 60’s-earlier)
GM 30
0 ohms
30 ohms
GM 0-90 ohm (mid 60’s-late 90’s)
GM 90
0 ohms
90 ohms
GM 40-250 ohm (late 90’s-later)
GM 250
40 ohms
249 ohms
GM 90-0 ohm (63-67 Corvette)
63 VET
90 ohms
0 ohms
FORD 73-10 ohm (earlier -late 80’s)
F 10
73 ohms
10 ohms
FORD 20-150 ohm (late 80’s-later)
F 150
20 ohms
150 ohms
VDO 10-180 ohm
V 180
10 ohms
180 ohms
SW/SUN 33-240
SW 33
240 ohms
33 ohms
User programmed
CUSTOM
User settable
User settable
To get into the fuel setup menus, start with the key off.
Press and hold SW1 while turning the key on, then release SW1.
Press and release SW1 to scroll though the setup menus until you get to “setup fuel”.
When “setup fuel” is displayed, press and hold SW1 until “fuel sender” is displayed, then
release SW1.
This is the start of the fuel setup menus, now make your selection between “SENDER” “custom
test” or “done”. When you get to the desired sub-menu, press and hold the switch to select it.
Fuel sensor setup (fuel sender)
This menu is used to select the fuel level sensor type. The table above shows the seven
options and resistance ranges as well as the custom option.
When fuel sender” is displayed, press and hold SW1 until you get “sender xx xx
where “xx xx” is the current sensor it is set to.
Release SW1, and the current sensor selection is displayed.
Press and release SW1 to scroll through the sensor options “gm 30 gm 90 GM 250
f 10 f 150 v 180 sw 33 Bus 63 vet custom
When the desired setting is displayed, press and hold SW1 until DONE” is displayed.
Release the switch to go onto the next menu item.
Note: You must calibrate the custom sensor curve to your specific fuel sensor. If you are
selecting the Custom setting follow the steps below to save your sensors resistance
curve.