When SIGNAL is displayed, press and hold SW1 to enter the SIGNAL setup menu
Release SW1 and the current setting will be displayed
Press and release SW1 to toggle from 12V HIGH to 5V LOW
When the desired setting is displayed, press and hold SW1 until DONE is displayed
Release the switch to go on to the next sub-menu item.
Exit tach setup (DONE)
This will allow you to exit the tach setup and go on to the next setup menu.
When TACH DONE is displayed, press and hold SW1 until DONE is displayed
Release the switch to go on to the next menu.
VOLT SETUP
The volt setup allows you set a warning point that will cause the volt display to flash
whenever the voltage drops below the warning value. The low voltage point can be set from 10 -
13.1 volts. There is only one thing to set in the volt sub-menu; either WARNING or DONE will
be displayed.
Press and hold SW 1 while turning the key on. Release the switch. Press and release
SW1 to get to the “volt” setup menu. Press and hold the switch until volt warning is
displayed to enter the volt setup menus, then release SW1.
When WARNING is displayed, press and hold SW1 until you see VOLT WARN LOW
followed by a number. Release SW1; this is the current voltage warning point.
Press and release SW1 to increase the value from 10.0 13.1
When the desired setting is displayed press and hold SW1 until DONE is displayed
Release the switch to go onto VOLT DONEPress and hold SW1 to exit VOLT setup
menu.
WATER TEMP SETUP
The water temp setup allows you select the units the temperature is displayed in,
Fahrenheit or Celsius. It also allows you to set a high temperature warning point that will cause
the message to display in LCD1 whenever the reading on the display is higher than the set point.
There is also a test mode that will display the resistance for the sensor for trouble shooting
assistance.
Press and hold SW1 while turning the key on. Release the switch. Press and release
SW1 to get to the “water” setup menu. Press and hold the switch until water sender is
displayed to enter the water setup menus, then release SW1.
Now you can press and release the switch to scroll through the water sub-menus,
SENDER” “WARNing” “test” “DONE”. When you get to the desired sub-menu press and hold the
switch to select it.
Temp sensor setup (SENDER)
This menu is used to set the temp sensor type. Dakota Digital only offers one temp sensor
for this system, it is SEN-04-5, 100-300 F(40-150 C), 1/8” NPT threads. You can use bushings to
adapt the sensor to various locations. You will select DD Fto read in Fahrenheit, or select DD
Cto read in Celsius.
You can also read the temp with the use of a bus interface module (BIM). Dakota Digital
offers a BIM-01-X that will allow you to read the engine temp signal from an ECU if you are
installing the system in a vehicle equipped with the OBDII port or a drivetrain from a newer
vehicle, most 1996 and newer vehicles have this. You will select “BUS F” to read in Fahrenheit,