Datasheet

The required room temperature is set by turning
the setting dial. The temperature scales below
shows the correlation between scale values and
the room temperature. The temperature values
stated are for guidance only as the obtained
room temperature will often be inuenced by
installation conditions.
The temperature scales are stated according
to European standards at Xp = 2°C. This means
that the radiator thermostats close at a sensor
temperature which is 2°C higher than stated on
the temperature scales.
Locking and limitation of the temperature
set-point of RA sensors are carried out using the
limiter pins placed at the back of the sensor.
Locking and max./min limitation of the remote
temperature adjuster are carried out by the
limiter tabs. The limiter tabs will be covered by
the setting dial.
The procedure is described in the instruction.
Setting the temperature
81620242
C12
123 4
5
Setting position
Room temperature
= Frost protection setting
Danfoss React™
Datasheet
4
Danfoss React™ Thermostatic sensors series
© Danfoss Climate Solutions | 01.2023 | AI419743092720en-000101