Product Overview

© Danfoss | DCS (im) | 2017.09
Data sheet | Pressure transmitter for marine applications, MBS 3100 and MBS 3150
4 | 520B8244 | IC.PD.P20.2O.02
MBS 31..
1
Gasket / O-ring material
0
No gasket
1
Gasket, Viton -20 °C – 125 °C
3
O-ring, Viton -20 °C – 125 °C
Pressure connection
Standard
0 0 A B 0 4
G ¼ A (EN 837), not MBS 3150!
With pulse-snubber
5 0 G B 0 4
DIN 3852 E – G ¼, Gasket: DIN 3869-14-NBR
A B 0 8
G ½ A (EN 837)
Measuring range
A C 0 4
¼ – 18NPT
-1 – 1.5 bar
8 4
-1 – 3.0 bar
8 5
Electrical connection
-1 – 5.0 bar
8 7
Figures refer to plug and standard PIN
conguration – see page 6
0 – 1.0 bar
1 0
0 – 1.6 bar
1 2 A9
Plug (EN 175301-803-A), GL, Pg 13.5
0 – 2.5 bar
1 4 F4
Cable screened, ship 2 m
0 – 4.0 bar
1 6 A1
Plug (EN 175301-803-A), Pg 9
0 – 6.0 bar
1 8 A6
Plug (EN 175301-803-A), Pg 11
0 – 10 bar
2 0 C8
Plug ISO 15170-A1-3.2-Sn
0 – 16 bar
2 2 E3
* EN 60947-5-2, M12 × 1, male excl. female plug
0 – 25 bar
2 4
0 – 40 bar
2 6
Output signal
0 – 60 bar
2 8 1
4 – 20 mA
0 – 100 bar
3 0
0 – 160 bar
3 2
0 – 250 bar
3 4
* ) Gauge versions only available as sealed gauge versions
0 – 400 bar
3 6
0 – 600 bar
3 8
Prefered version
Pressure reference
Gauge (relative)
1
Absolute
2
Ordering standard
Non-standard build-up
combinations may be selected.
However, minimum order
quantities may apply.
Please contact your local
Danfoss oce for further
information or request
on other versions.