© Danfoss A/S (AC-MCI/sw) 2013-11 DKRCC.PD.AXV.A9.02 / 520H8187 11
Data sheet Thermostatic expansion valves, type TGE
Ordering
Standard range (continued)
Valve
type
Orice
no.
Nominal
capacity
Q
nom.
2)
Inch version mm version
Connection
Solder
ODF × ODF
1)
in.
Code no.
Multi pack
Connection
Solder
ODF × ODF
1)
mm
Code no.
Multi pack
kW TR
TGEL 10
3
12 3.5
3
/
8
×
5
/
8
067N3000 10 × 16 067N3040
TGEL 10
3
12 3.5
1
/
2
×
5
/
8
067N3001 12 × 16 067N3041
TGEL 10
4
16 4.5
1
/
2
×
7
/
8
067N3002 12 × 22 067N3042
TGEL 10
6
24 6.5
1
/
2
×
5
/
8
067N3003 12 × 16 067N3043
TGEL 10
6
24 6.5
1
/
2
×
7
/
8
067N3004 12 × 22 067N3044
TGEL 10
6
24 6.5
5
/
8
×
7
/
8
067N3005 16 × 22 067N3045
TGEL 10
8
32 9
5
/
8
×
7
/
8
067N3006 16 × 22 -
TGEL 10
11
45 13
5
/
8
×
7
/
8
067N3007 16 × 22 -
TGEL 10
11
45 13
5
/
8
× 1
1
/
8
067N3008 16 × 28 067N3048
TGEL 20
12.5
54 15
5
/
8
×
7
/
8
067N3009 16 × 22 067N3049
TGEL 20
12.5
54 15
5
/
8
× 1
1
/
8
067N3010 16 × 28 067N3050
TGEL 20
16
68 19
5
/
8
× 1
1
/
8
067N3011 16 × 28 067N3051
TGEL 20
16
68 19
7
/
8
× 1
1
/
8
067N3012 22 × 28 067N3052
TGEL 20
20
79 23
7
/
8
× 1
1
/
8
067N3013 22 × 28 067N3053
TGEL 20
20
79 23
7
/
8
× 1
3
/
8
067N3014 22 × 35 067N3054
TGEL 40
26
110 31
7
/
8
× 1
3
/
8
067N3015 22 × 35 067N3055
TGEL 40
26
110 31
1
1
/
8
× 1
3
/
8
067N3016 28 × 35 067N3056
TGEL 40
30
125 35
7
/
8
× 1
3
/
8
067N3017 22 × 35 067N3057
TGEL 40
30
125 35
1
1
/
8
× 1
3
/
8
067N3018 28 × 35 -
TGEL 40
40
161 46
1
1
/
8
× 1
3
/
8
067N3019 28 × 35 067N3059
Only solder versions, connection size <=22mm / 7/8 in. are approved
for ammable refrigerants.
Range N = -40 +10 °C/-40 50 °F, OS = 4 K/7.2 °F
R410A/R32
Valve
type
Orice
no.
Nominal capacity Q
nom.
2)
Inch version mm version
R410A R32
Connection
Solder
ODF × ODF
1)
in.
Code no.
Multi pack
Connection
Solder
ODF × ODF
1)
mm
Code no.
Multi pack
kW TR kW TR
TGEL 10
3
12 3.5 18 5
3
/
8
×
5
/
8
067N3150 10 × 16 067N3190
TGEL 10
3
12 3.5 18 5
1
/
2
×
5
/
8
067N3151 12 × 16 067N3191
TGEL 10
4
16 4.5 24 7
1
/
2
×
7
/
8
067N3152 12 × 22 067N3192
TGEL 10
6
24 6.5 35 10
1
/
2
×
5
/
8
067N3153 12 × 16 067N3193
TGEL 10
6
24 6.5 35 10
1
/
2
×
7
/
8
067N3154 12 × 22 067N3194
TGEL 10
6
24 6.5 35 10
5
/
8
×
7
/
8
067N3155 16 × 22 067N3195
TGEL 10
8
32 9 47 13
5
/
8
×
7
/
8
067N3156 16 × 22 067N3196
TGEL 10
11
45 13 68 19
5
/
8
×
7
/
8
067N3157 16 × 22 067N3197
TGEL 20
12.5
54 15 81 23
5
/
8
×
7
/
8
067N3159 16 × 22 067N3199
Range N = -40 +10 °C/-40 50 °F, OS = 4 K/7.2 °F R410A
TGEL 10
11
45 13
5
/
8
× 1
1
/
8
067N3158 16 × 28 067N3198
TGEL 20
12.5
54 15
5
/
8
× 1
1
/
8
067N3160 16 × 28 067N3200
TGEL 20
16
68 19
5
/
8
× 1
1
/
8
067N3161 16 × 28 067N3201
TGEL 20
16
68 19
7
/
8
× 1
1
/
8
067N3162 22 × 28 067N3202
TGEL 20
20
79 23
7
/
8
× 1
1
/
8
067N3163 22 × 28 067N3203
TGEL 20
20
79 23
7
/
8
× 1
3
/
8
067N3164 22 × 35 067N3204
TGEL 40
26
110 31
7
/
8
× 1
3
/
8
067N3165 22 × 35 067N3205
TGEL 40
26
110 31
1
1
/
8
× 1
3
/
8
067N3166 28 × 35 -
TGEL 40
30
125 35
7
/
8
× 1
3
/
8
- 22 × 35 067N3207
TGEL 40
30
125 35
1
1
/
8
× 1
3
/
8
067N3168 28 × 35 -
TGEL 40
40
161 46
1
1
/
8
× 1
3
/
8
067N3169 28 × 35 067N3209
1)
Pressure equalisation =
1
/
4
in (6 mm) ODF
2)
The nominal capacity is based on: ARI standard
Evaporating temperature, T
e
= 4.4 °C/40 °F
Liquid temperature, T
l
= 37 °C/ 99 °F
Condensing temperature, T
c
= 38 °C/100 °F
Opening surperheat, OS = 4 K/7.2 °F
R410A
Range K = -25 +10 °C/-15 +50 °F
with MOP 165 psig/11.5 bar abs, OS = 4 K/7.2 °F