Installation Manual

Find the Required Cable Length
Table 1 -
Summary of Cable Lengths
Item
Required Cable Length (ft)
Remarks
Roof Edge (Fig.A)
See Table 2
Multiplier depends on roof overhang
Dormer Perimeter
1’ per linear foot
Measure dormer perimeter
Roof Valley
6’ minimum
Per valley 3’ up, 3’ down
Gutter
1’ per linear foot gutter
Measure gutter length
Downspout
2’ per linear foot of downspout
Cable loops down and up
Table
2 -
Cable Length Multipliers and Roof Overhang
Eave Overehang “O”
Loop Height “H”=”O”+6
Roof Multiplier
12”
18”
1.9
24”
30”
2.7
36”
42”
3.6
48”
54”
4.6
See Figure A for standard roof
Table 3 Cable Length Calculations
Section
Calculation
Cable Length (ft)
1. Roof
______ x _________
Length
x
Multiplier
2. Dormers
______ x __________________
Number of x (sum
up, over and down)
3. Valleys
_____
x
_
6’__
Number of x
6’
4. Gutters*
_____ x
_
1’__
Length
x
1’
5. Downspouts
______ x __________
Number of x
(2 x height)
Total
__________________
Part Numbers
Appendix A
H
O
RX Kits - 120V
*For gutters more than 4” wide, make two traces of RX cable in the gutter, ie multiply those gutter lengths
with widths >4” by 2.
Remember to make accurate measurements of the roof, overhang, gutters, valleys, and downspouts to enter
into the table above.
Fig. A
EXAMPLE:
24’ roof with overhang
24” use multiplier 2.7 i.e.
Cable length = 24’ x 2.7
= 64.8’
No dormers exist on this
roof
2 Valleys (x6’) = 12’
24’ gutter with 1 down
spout, 10’ in height
= 24’ x 1 = 24’
and 1 x (2 x 10’)
= 20’
Therefore total cable:
64.8’ + 12’ + 24’ + 20’
= 120.8’ (088L3505)
Part No.
Length
(feet)
Watts Amps Ohms
088L3500 30 170 1.4 85.7
088L3502 65 310 2.6 46.2
088L3503 80 390 3.3 36.4
088L3504 100 450 3.8 26.7
088L3505 120 535 4.5 23.1
088L3508 170 760 6.3 19.0
088L3510 230 1080 9.0 13.3
088L3511 265 1220 10.2 11.8
No. Shingle
Clips / Kit
25
25
50
50
75
100
100
125
Each kit comes with 10 spacer clips as standard.
11
TEL: 866-676-8062. FAX: 905-285-2055
Copyright 2009 Danfoss Inc.
088L3371- 07/2009
Danfoss can accept no responsibility for possible errors in catalogues, brochures, other printed materials, and website information. Danfoss reserves the right to alter its products without
notice. This also applies to products already on order provided that such alteration can be made without subsequent changes being necessary in specifications already agreed upon. All
trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are registered trademarks of Danfoss A/S. All rights reserved.
Danfoss Inc.
Toronto
Toll Free: 866-676-8062
Phone: 905-285-2050
Fax: 905-285-2055
www.LX.Danfoss.com
Danfoss
RX
BRINGING WARMTH TO LIFE