IMPORTANT! DO NOT CROSS OR CUT THE HEATING CABLE. REMEMBER TO MEASURE, VERIFY AND RECORD THE RESISTANCE. USE A MEGGER TO TEST THE RESISTANCE TO GROUND.
Table of Contents Danfoss TX-FH Electric Floor Heating System .......................................... 2 Danfoss TX-FH Cable Specifications ............................................................ 3 Measuring the Resistance ............................................................................... 3 General Notes....................................................................................................... 4 General TX-FH Cable Installation Guidelines......................................
Danfoss TX-FH Electric Floor Heating System Danfoss TX-FH Electric Floor Heating System Danfoss TX-FH cables are a thick floor heating solution. Thick cables have a larger diameter than the Danfoss LX floor heating cables, allowing them to be lower in COST, higher in HEAT OUTPUT, and more DURABLE. They are installed in mud beds below the flooring materials and are most often used in new construction where overall material cost is a primary concern.
Products Danfoss TX-FH Specifications Type: Voltage: Output: Heating Element Size: Power Lead Cable Diameter: Wire insulation: Outer insulation: Max. Allowable Temp.: Min. Installation Temp.: Twin conductor 240V 6 W/ft (20 W/m) 60 ft (18 m) to 680 ft (207 m) 10 ft (3.0 m) 1/4 in ( 6 mm ) FEP, TeflonTM PVC 220°F (105°C) 40°F (5°C) Note : TX-FH cables operated on a 208V power supply will experience a 25% power reduction.
GENERAL NOTES Read before beginning installation! Copyright 2009 Danfoss Inc. The installation shall be in accordance with the manufacturer's instructions and national and local electrical codes. The installation shall be in accordance with Part 424, American National Standard Institute / National Fire Protection Association (ANSI/NFPA70), National Electrical Code (NEC) and Canadian Electrical Code (CEC). Danfoss recommends GFCI for heating cables in normally wet areas ( i.e.
GENERAL NOTES ( continued ) Read before beginning installation! Measure, verify and record the actual resistance throughout the installation process: 1. 2. 3. 4. Out of the box After installation After laying the mud bed After connecting thermostat and/or contactors Record these values in the warranty card. Failure to do so will void the Copyright 2009 Danfoss Inc. warranty; The Danfoss TX-FH electric heating system is most effective with tiled or stone or concrete floors.
General TX-FH Cable Installation Guidelines Cable Strapping Should the Danfoss cable strapping ( part # 088L1051, # 088L1050 ) be used for the TX-FH cable, follow the instructions below for ease of installation. Secure the Danfoss strapping to the ground surface (3 feet apart) Place the TX-FH cable Clip the TX-FH cable in place Installing the heating cable The TX-FH cable must be laid out with even spacing over the entire area to be heated.
Danfoss TX-FH Installation - Step by Step STEP 1: PLAN YOUR LAYOUT Make a sketch of the area to be covered with heating TX-FH cables. Accurately measure the net area of the floor. This is the area you would walk upon. Do not install heating cable under the permanent fixtures. Select the cable spacing. Never space cables closer than 4” apart . Danfoss recommends 6” standard spacing. You should also plan the location of the thermostats, floor sensors locations and their conduit’s location.
Danfoss TX-FH Installation (Continued) STEP 5: INSTALL THE FLOOR COVERINGS Apply the mortar bed . Ensure that the contractors are careful not to damage the cable with tools, heavy bucket of cement , etc. When you are done installing the tile measure the resistance and record the information on the warranty card. It is not recommended to power the cables for until the tile adhesive has cured (approximately 30 days). Check with the tile adhesive manufacturer for exact curing times.
EXTENDED WARRANTY For a period of ten (10) years from the date of purchase Danfoss warrants that the Danfoss TX-FH cable is free from defects in material, design and workmanship. The extended warranty is only valid if the warranty certificate has been properly completed and mailed, and the installation is in accordance with the installation instructions. The defective Danfoss TX-FH cable has to be inspected by or submitted to Danfoss or an authorized Danfoss TX-FH dealer.
APPENDIX A 10" to 15" LAYOUT EXAMPLE Start T 6" End Copyright 2009 Danfoss Inc. NA.EFHTH-FHM- 07/2009 TEL: 866-676-8062.
Danfoss can accept no responsibility for possible errors in catalogues, brochures, other printed materials, and website information. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alteration can be made without subsequent changes being necessary in specifications already agreed upon. All trademarks in this material are property of the respective companies.