User Guide
Table Of Contents
- 2. Menu Overview
- 3. Introduction
- 4. General Operation
- 5. Ground Fault: (GFCI) 1/2
- 5. Ground Fault: (GFCI) 2/2
- 6. Icons 1/2
- 6. Icons 2/2
- 7. Startup Wizard
- 8. Programed Heating Schedule
- 9. Operating Choices
- 10. Thermostat Setup Menu 
- 10.1 Heating Schedule 1/2 
- 10.1 Heating Schedule 2/2 
- 10.2 Energy Use 
- 10.3. User Settings 
- 10.4 Installer Settings 
- 10.4.1 Adaptive Function 
- 10.4.2 Open Window 
- 10.4.3 Sensor Application 1/2 
- 10.4.3 Sensor Application 2/2 
- 10.4.4 Sensor Type 1/2 
- 10.4.4 Sensor Type 2/2 
- 10.4.5 Floor Sensor Calibration 
- 10.4.6 Room Sensor Calibration 
- 10.4.7 Floor Protection 1/2 
- 10.4.7 Floor Protection 2/2 
- 10.4.8 Factory Reset 
- 11. Factory Settings
- 12. Troubleshooting 1/2
PAGE 51
© 2015 OJ Electronics A/S
10.4.2 Open Window
This option allows you to enable the “Open Window” function.
The thermostat can detect an open window by registering a rapid drop in
temperature.
With the function enabled, the thermostat shuts o the heating for 30 minutes if an
open window is detected.
1. Tap the “Menu” button on the home screen.
2. Then tap the “Installer Settings” button to access the various installer settings.
3. Tap the “Open Window” button.
4. Tap the “OFF/ON” button to the setting that you prefer.
5. Confirm your choice with “√” or discard it with “X”.
The thermostat will automatically return to “Installer Settings”.
6. If an open window is detected by the thermostat, the “Open Window” screen
will appear, the function can be canceled by tapping “Cancel”.
Note: Open Window is not available with software version 1012N100
1
2
3
4
5
6
1
>
<