5.6 Reading off temperatures
OP. DATA
OUTDOOR
ROOM
SUPPLY LINE
RETURN LINE
DISTR. CIRC. 1
SYSTEM SUPPLY
DISTR. CIRC. 2
0˚C
20˚C
38(40)˚C
34(55)˚C
35(40)˚C
32(35)˚C
28(30)˚C
The set point value for the supply line and the
max value of the return line is shown within
brackets The max value indicates the tempera-
ture at which the compressor is stopped. No val-
ues can be changed in this menu.
The different temperatures that the installation has are shown here. All
temperatures are stored back in time so that they can also be displayed
in the form of graphs.
If ROOM shows 20°C the heat curve is unaffected. If ROOM shows higher
or lower, this indicates that the heat curve has been adjusted up or
down.
5.7 Reading the operating time
OH
OH
OH
OH
OH
OH
OH
OPERAT. TIME
COMPRESSOR
OHCOMPRESSOR SL
HEATING
COOLING
AUX. HEAT 1
AUX. HEAT 2
AUX. HEAT 3
OH
EXT.AUX.HEATER
HOT WATER
COMPRESSOR shows the total time in hours that the heat pump has
been in operation since installation.
AUX. HEAT 1, 2 and 3 refer to the immersion heater and its different
power stages.
5.8 Manual defrost, outdoor unit
If the heat pump requires defrosting you can run a defrosting procedure
manually from the control computer.
To defrost manually: