Operating instructions

The attributes supported are listed below.
Attribute Access Stub/
Full
Name Data type Description
1 Set/Get Stub Parameter value
Data type
1
Actual value of parameter
2 Get Stub Link path size USINT Size of link path
3 Get Stub Link path ARRAY DeviceNet's path to parameter's origin
Segment type/
port
BYTE
Segment Ad-
dress
Path
4 Get Stub Descriptor WORD Description of parameter
5 Get Stub Data type EPATH Data type code
6 Get Stub Data size USINT Number of bytes in parameter value
7 Get Full Parameter name
string
SHORT
STRING
Human readable text string representing pa-
rameter name
8 Get Full Units string SHORT
STRING
Human readable text string representing pa-
rameter name
9 Get/Set Full Help string SHORT
STRING
Human readable text string representing pa-
rameter name
10 Get Full Min value
Data type
1
Min valid value
11 Get Full Max value
Data type
1
Max valid value
12 Get Full Default value
Data type
1
Parameters default value
13 Get Full Scaling multiplier UINT Multiplier for scaling factor
14 Get Full Scaling divisor UINT Divisor for scaling factor
15 Get Full Scaling base UINT Base for scaling formula
16 Get Full Scaling offset INT Offset for scaling formula
17 Get Full Multiplier link UINT Parameter instance of multiplier source
18 Get Full Divisor link UINT Parameter instance of divisor source
19 Get Full Base link UINT Parameter instance of base source
20 Get Full Offset link UINT Parameter instance of offset source
21 Get Full Decimal preci-
sion
USINT Specifies parameter value format
1
= Same data type as the parameter.
FC 100/ 200/ 300 DeviceNet 5. How to Access the Parameters
MG.33.D3.02 - VLT
®
is a registered Danfoss trademark
45