MAKING MODERN LIVING POSSIBLE VLT 5000 Profibus to FC 302 converter VLT® AutomationDrive FC 300
VLT® AutomationDrive PROFIBUS Converter Contents Safety Note ................................................................................................................... 3 Introduction ........................................................................................................................... 4 About this Manual ........................................................................................................... 4 Technical Overview ...........................................
VLT® AutomationDrive PROFIBUS Converter Copyright, Limitation of Liability and Revision Rights This publication contains information proprietary to Danfoss A/S. By accepting and using this manual the user agrees that the information contained herein will be used solely for operating equipment from Danfoss A/S or equipment from other vendors provided that such equipment is intended for communication with Danfoss equipment over an PROFIBUS serial communication link.
VLT® AutomationDrive PROFIBUS Converter Safety Note The voltage of the frequency converter is dangerous whenever connected to mains. Incorrect installation of the motor, frequency converter or fieldbus may cause damage to the equipment, serious personal injury or death. Consequently, the instructions in this manual, as well as national and local rules and safety regulations, must be complied with. Safety Regulations 1.
VLT® AutomationDrive PROFIBUS Converter Introduction About this Manual First time users can obtain the most essential information for quick installation and set-up in these chapters: Technical Overview Constrains How to Install For more detailed information including the full range of set-up options and diagnosis tools please refer to the chapters: How to Configure the System Parameter Mapping List MG.34.N1.
VLT® AutomationDrive PROFIBUS converter - I n t r o d u c t i o n - Technical Overview This VLT® 5000 to FC 302 converter (MCA114) is a option intended for replacing a VLT® 5000 with a FC 302 Automation Drive, in a PROFIBUS network. With this PROFIBUS converter option the FC 302 will react as a VLT® 5000 on the PROFIBUS network; it means that it will in most cases not be necessary to change anything in the PLC programming or configuration.
VLT® AutomationDrive PROFIBUS converter - I n t r o d u c t i o n - Constrains Software versions • • The converter requires a FC 302 with a minimum drive-software version 5.5X. The converter software is based on a VLT® 5000 ver. 3.9x software and PROFIBUS ver. 4.5 software. Hardware • • • • MCA114 only supports FC 302 only. There is no support for PROFIBUS FMS networks. The FC 302 has fewer digital I/O’s and analogue output signals compared to VLT® 5000.
VLT® AutomationDrive PROFIBUS converter - I n t r o d u c t i o n - Performance Main Actual Value (MAV) is calculated different, compared to VLT® 5000. The motor control algorithm of®the FC 300 is still used and will result in a better motor performance compared to VLT 5000. • • N.B. Factory values: After initialisation most parameters are set to match the factory settings of the VLT® 5000 parameters. N.B.
VLT® AutomationDrive PROFIBUS converter - I n t r o d u c t i o n - Abbreviations AOC CTW EMC I/O LED LSB MAV MOC MSB MRV N/A PCD PCV Application oriented control Control word Electromagnetic Compatibility Input/Output Light Emitting Diode Least Significant Bit Main Actual Value (actual output) Motor oriented control Most Significant Bit Main Reference Value Not applicable Peripherals Communication Data (process data) Parameter Characteristics (Parameter channel) PLC PNU PPO PPO1 PPO3 PU REF STW Progra
VLT® AutomationDrive PROFIBUS converter How to Install The MCA114 PROFIBUS converter Option Connecting the Bus Line Proper termination of the bus line is essential. A mismatch of impedance may result in reflections on the line that will corrupt data transmission. - The PROFIBUS Option Card has a suitable termination, activated by switch 1 located on the PROFIBUS converter option. The switches must be on to terminate the bus. The factory setting is off.
VLT® AutomationDrive PROFIBUS converter How to Install Option in Frequency Converter To install a fieldbus option in the drive you will need: The fieldbus option Fieldbus option adaptor frame for the FC 300. This frame is deeper than the standard frame, to allow space for the fieldbus option beneath. Cable holders Instructions: Remove the LCD panel from the FC 300. Remove the frame located beneath and discard. Push the option into place.
VLT® AutomationDrive PROFIBUS converter How to Configure the System Configure the PROFIBUS Network All PROFIBUS stations that are connected to the same bus network must have a unique station address. ® Before a VLT 5000 can be replaced with a FC 302 with MCA114, only the station address needs to be configured in the FC 302.
VLT® AutomationDrive PROFIBUS converter Setting the PROFIBUS Address via Parameter 9-18 : Node address Setting the address via parameter 9-18 Node address or the PROFIBUS SSA-command is possible, if the hardware switches are set to 126 or 127 (factory switch setting). The address change will come into effect at the next power-up. Commissioning After copying the station address from the VLT® 5000 to the FC 302, power must be cycled to the FC 302.
VLT® AutomationDrive PROFIBUS converter LED Behaviour The option has 2 bi-coloured LED’s: LED label NS MS Description Network Status Module Status (DP-V1 communication) NS: Net Status State LED Power On Baud rate search Wait Parameterizing Wait Configuration Data Exchange Description Red: ██████████████ Solid red Green: █ █ █ █ █ █ Flashing green Green: █ █ █ █ █ █ Flashing green Green: ████ ████ ██ Long green flash Red: ████ ████ ███ Long red flash Green: █ █ █ Short green
VLT® AutomationDrive PROFIBUS converter EMC Precautions The following EMC precautions are recommended in order to achieve interference-free operation of the PROFIBUS. Additional EMC information is available in the FC 300 series Design Guide. N.B.: Relevant national and local regulations, for example regarding protective earth connection, must be observed.
VLT® AutomationDrive PROFIBUS converter Parameter Mapping List VLT ® 5000 Group 0 Parameter number Parameter name Data values Parameter number Parameter name Data values 5000 series FC 300 series 001 Language Select [0] English [1] Deutsch [2] French [3] Dansk [4] Spanish [5] Italian 001 Language [0] English [1] Deutsch [2] French [3] Dansk [4] Spanish [5] Italian 5000 series FC 300 series 5000 series FC 300 series 002 Local/remote control [0] Remote [1] Local with External Stop [2] Local Par
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter number Parameter name Data values Parameter number Parameter name Parameter number Parameter name 5000 series FC 300 series 005 Set-up Selection, Programming [0] Factory Set-up [1] Set-up 1 [2] Set-up 2 [3] Set-up 3 [4] Set-up 4 [5] Active Set-up 970 Edit Set-up 5000 series FC 300 series 5000 series FC 300 series 006 Setup Copy 0] Factory Set-up 1] Set-up 1 2] Set-up 2 3] Set-up 3 4] Set-up 4 9] Active Set-up [ [ [ [
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – 20] Pulse reference [Hz] 21] Ext. reference [%] 22] Status word [hex] 23] Brake effect/2 min [kW] [24] Brake effect/sec [kW] [ [ [ [ [mA] [1651] Pulse reference [Hz] [1650] Ext. reference [%] [1603] Status word [hex] [1633] Brake effect/2 min [kW] [1632] Brake effect/sec [kW] [1634] Heat sink temp. 25] Heat sink temp. 26] Alarm word [hex] 27] Control word [hex] 28] Warning word 1 [hex] 29] Warning word 2 [hex] 30] Com.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Data values Parameter number Parameter name Data values Parameter number Parameter name Data values VLT 0 Not locked 1 Lock 0 Full access 1 LCP: Read only [ ] [ ] [ ] [ ] 5000 series FC 300 series 5000 series FC 300 series 019 004 Power-Up Mode Operating state at power up [0] Auto Restart, use saved [0] Resume ref. [1] Forced stop, use saved [1] Forced stop, use saved ref. ref. [2] Forced stop, set ref = 0.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – [4] High variable torque high [5] High special motor characteristic [6] High variable torque with low starting torque [7] High variable torque with medium starting torque [8] High variable torque with high starting torque [11] Normal constant torque [12] Normal variable torque low [13] Normal variable torque medium [14] Normal variable torque high [15] Normal special motor characteristic [16] Normal variable torque with low constant st
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – with high constant starting torque 5000 series Parameter number Parameter name Data range 102 Motor Power 0.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Data range 0.1 – 10.0 Hz Parameter number Parameter name 113 Load compensation at low speed 0 – 300 % Data range Parameter number Parameter name 5000 series 5000 series 0.3 – 10.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter number Parameter name Data values 121 Start function [0] DC hold in start delay time [1] DC brake in start delay time [2] Coasting in start delay time [3] Start frequency/voltage clockwise [4] Start frequency/voltage in reference direction [5] VVC+ clockwise 5000 series Parameter number Parameter name Data values 122 Function at stop [0] Coasting [1] DC hold [2] Motor check [3] Pre-magnetizing Parameter number Parameter name
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – 5000 series FC 300 series Parameter number Parameter name Data values 128 Motor thermal protection [0] No protection [1] Thermistor warning [2] Thermistor trip [3] ETR warning 1 [4] ETR trip 1 [5] ETR warning 2 [6] ETR trip 2 [7] ETR warning 3 [8] ETR trip 3 [9] ETR warning 4 [10] ETR trip 4 Parameter number Parameter name Data values 129 External motor fan [0] No [1] Yes Parameter number Parameter name Data range 130 Start frequenc
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – VLT ® 5000 Group 2 Parameter number Parameter name Data values 5000 series 200 Output Frequency Range/Direction [0] Only clockwise, 0 – 132 Hz [1] Both directions, 0 – 132 Hz [2] Only clockwise, 0 – 1000 Hz [3] Both directions, 0 – 1000 Hz [4] Only counter clockwise, 0 – 132 Hz [5] Only counter clockwise, 0 – 1000 Hz 5000 series FC 300 series 410 Motor Speed Direction 0 Clockwise [ ] 2 Both directions [ ] 0 Clockwise [ ] 2 Both
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter number Parameter name Data Values: 5000 series 206 Ramp Type [0] Linear 1 Sine shape (S1) [ ] 2 Sin2 Shape (S2) [ ] 3 Sin3 Shape (S3) [ ] 4 Sin2 filter [ ] Parameter number Parameter name Data range 5000 series 207 Ramp up Time 1 0.05 – 3600.00 sec FC 300 series 340, 350, 382 Ramp Type [0] Linear. Write to p.340, 350 and 382 Par. 345 = 1% Par. 346 = 25% Par. 347 = 1% Par. 348 = 25% Par. 350 = 2 Par. 355 = 1% Par.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – 5000 series FC 300 series Parameter number Parameter name Data range 208 Ramp down Time 1 0.05 – 3600.00 sec Parameter number Parameter name Data range 209 Ramp up Time 2 0.05 – 3600.00 sec Parameter number Parameter name Data range 210 Ramp down Time 2 0.05 – 3600.00 sec Parameter number Parameter name Data range 211 Jog ramp time 0.05 – 3600.00 sec Parameter number Parameter name Data range 212 Quick stop ramp time 0.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Data range -100,00 - 100,00 % Parameter number Parameter name Data range 219 Catch up/slow down value 0.00 – 100 % 312 Catch up/slow down value 0.00 – 100 % Parameter number Parameter name Data range 221 416 Torque limit for motor mode Torque limit for motor mode 0.0 – Max. torque % 0.0 – Max. torque % 5000 series FC 300 series Parameter number Parameter name Data range 222 Torque limit for generating mode 0.0 – Max.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – 5000 series Parameter number Parameter name Data range 230 Frequency Bypass 1 0 – par. 200 Parameter number Parameter name Data range 231 Frequency Bypass 2 0 – par. 200 Parameter number Parameter name Data range 232 Frequency Bypass 3 0 – par. 200 Parameter number Parameter name Data range 233 Frequency Bypass 4 0 – par.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – 5000 series Parameter number Parameter name 301 Terminal 17, input Data values [0] Comments FC 300 series 517 (MCB 101) Terminal X30/3 Digital Input [0] No operation [1] Reset [6] Stop inverse [13] Enable start reverse No function [1] Reset [2] Stop inverse [3] Only start anticlockwise, on [4] Jog [14] Jog [5] Preset reference, on [15] Preset reference, on [6] Preset reference, msb [17] Preset reference bit 1 [7] Freeze reference [
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter number Parameter name Data values Parameter number Parameter name Data values Parameter number Parameter name Data values 5000 series 305 Terminal 29, input [0] No function [1] Reset [2] Stop inverse [3] Only start clockwise, on [4] Only start anticlockwise, on [5] Jog [6] Preset reference, on [7] Preset reference, lsb [8] Preset reference, msb [9] Freeze reference [10] Freeze output [11] Speed up [12] Speed down [13] Choice
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – [3] Only start anticlockwise, on [4] Jog [5] Preset reference, on [6] Preset reference, msb [7] Freeze reference [8] Freeze output [9] Speed down [10] Choice of Setup, msb [11] Choice of Setup, msb / Speed down [12] Slow down [13] Ramp 2 [14] Mains failure inverted [24] Pulse feedback [25] Encoder input 2B [29] Data change lock 5000 series Parameter number Parameter name 308 Terminal 53, Analogue Input Voltage Data values [0] No Operat
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter number Parameter name Data values 5000 series 311 Terminal 54, Analogue Input Voltage 316, 420, 193, 421 316 Reference resource 2 700 Speed PID Feedback Source 420 Torque Limit Factor Source 193 Thermistor Resource 421 Speed Limit Factor Source [0] No Operation Par. 316 Reference resource 2 set to [0] No function Par. 316 Reference resource 1 [1] Reference set to [2] Analog input 53 Par.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – 5000 series FC 300 series Parameter number Parameter name Data range 315 Terminal 60, min. scaling 0.0 – 20.0 mA Parameter number Parameter name Data range 316 Terminal 60, max. scaling 0.0 – 20.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – [9] Alarm [10] Alarm or Warning Par. 532 = [9] Alarm Par. 532 = [10] Alarm or Warning [11] Torque limit Par. 532 = [11] At torque limit [12] Out of current range Par. 532 = [12] Out of current range [13] Above I low Par. 532 = [13] Below current, low [14] Under I high Par. 532 = [14] Above current, high [15] Out of frequency range Par. 532 = [15] Out of speed range [16] Over f low Par. 532 = [16] Below speed low [17] Under f high Par.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – 32000 p [42] Ref min – Ref max => 0 – 20 mA [43] Ref min – Ref max => 4 – 20 mA [44] Ref min – Ref max => 0 - 32000 p [45] FB min – FB max => 0 – 20 mA [46] FB min – FB max => 4 – 20 mA [47] FB min – FB max => 0 - 32000 p [48] 0 – I max => 0 – 20 mA [49] 0 – I max => 4 – 20 mA [50] 0 – I max => 0 – 32000 p [51] 0 – T lim => 0 – 20 mA [52] 0 – T lim => 4 – 20 mA [53] 0 – T lim => 0 – 32000 p [54] 0 – T nom => 0 – 20 mA [55] 0 – T nom => 4 –
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter number Parameter name Data range Parameter number Parameter name Data range Parameter number Parameter number Parameter name Data values 5000 series 320 Terminal 42 Output, pulse scaling 1 – 32000 Hz 5000 series FC 300 series 568 Pulse Output Max Freq #X30/6 (MCB 101) 0 – 32000 Hz FC 300 series 322 Terminal 45 Output, pulse scaling 1 – 32000 Hz 568 Pulse Output Max Freq #X30/6 (MCB 101) 0 – 32000 Hz 5000 series FC 300 ser
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – feedback low Par. 540.0 = [17] Above feedback high [21] Thermal warning Par. 540.0 = [21] Thermal warning [22] Ready, no thermal Par. 540.0 = [12] Ready,no warning thermal W [23] Ready - remote control Par. 540.0 = [23] Remote, - no thermal warning ready, no TW [24] Ready – mains voltage Par. 540.0 = [24] Ready, within range Voltage OK [25] Reversing Par. 540.0 = [25] Reverse [26] Bus OK Par. 540.
VLT® AutomationDrive PROFIBUS converter Data range - Parameter Mapping List – 1 – 4096 pulses Revolution 1 – 4096 pulses 5000 series FC 300 series Parameter number Parameter name 330 Freeze ref. /output function Parameter number Parameter name 345 Encoder loss timeout Data range 0.0 – 60.0 sec 432 Motor Feedback Loss Timeout 0.00 – 60.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – VLT ® 5000 Group 4 Parameter number Parameter name Data values 5000 series 400 Brake function/over voltage cont.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – 5000 series FC 300 series Parameter number Parameter name Data range 406 Automatic restart time 0 – 10 sec Parameter number Parameter name Data values 407 Mains failure [0] No function [1] Controlled ramp down [2] Controlled ramp down and trip [3] Coast [4] Kinetic back-up [5] Controlled alarm suppression 14-10 Mains Failure [0] No function [1] Controlled ramp down [2] Controlled ramp down and trip [3] Coast [4] Kinetic back-up [5] K
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter number Parameter name Data values Factory setting Parameter number Parameter name 5000 series FC 300 series 413 Over modulation function [0] Off [1] On [0] Off 14-03 Over modulation function [0] Off [1] On [1] On 5000 series FC 300 series 5000 series FC 300 series 414 Minimum feedback Parameter number Parameter name 415 Maximum feedback Parameter number Parameter name Data Value 416 Feedback Unit [0] None [1] % [2] P
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – 32] ft3/min 33] gal/h 34] ft3/h 35] lb/s 36] lb/min 37] lb/h 38] lb ft 39] ft/s 40] ft/min 126] ft3/min 123] gal/h 127] ft3/h 130] lb/s 131] lb/min 132] lb/h 150] lb ft 140] ft/s 141] ft/min [ [ [ [ [ [ [ [ [ [ [ [ [ [ [ [ [ [ 5000 series FC 300 series Parameter number Parameter name Data range 417 702 Speed PID proportional gain Speed PID proportional gain 0.000 – 0.150 0.000 – 1.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – 5000 series Parameter number Parameter name Data range 426 F2 frequency 0.0 – par. 104 Parameter number Parameter name Data range 427 U3 voltage 0.0 – par. 103 Parameter number Parameter name Data range 428 F3 frequency 0.0 – par. 104 Parameter number Parameter name Data range 429 U4 voltage 0.0 – par. 103 Parameter number Parameter name Data range 430 F4 frequency 0.0 – par.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter number Parameter name Data values 438 Process PID Anti windup [0] Off [1] On 731 Process PID Anti Windup [0] Off [1] On Parameter number Parameter name Data range 439 732 Process PID start frequency Process PID Start Speed Fmin – fmax 0 – 6000 rpm 5000 series FC 300 series Parameter number Parameter name Data range 440 Process PID proportional gain 0.00 – 10.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter number Parameter name 448 Gear ratio Not converted 5000 series FC 300 series 5000 series FC 300 series 5000 series FC 300 series 5000 series FC 300 series 5000 series FC 300 series Parameter number Parameter name 449 Friction loss Parameter number Parameter name Data range 450 14-11 Mains voltage at mains fault Mains Voltage at Mains Fault 180 – 690 Volt 100 – 800 Volt Parameter number Parameter name 453 707 Gea
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – VLT ® 5000 Group 5 5000 series Parameter number Parameter name Data range 500 Address 0 – 126 Parameter number Parameter name Data values 501 Baud rate [0] 300 [1] 600 [2] 1200 [3] 2400 [4] 4800 [5] 9600 Parameter number Parameter name Parameter number Parameter name Parameter number Parameter name Parameter number Parameter name Parameter number Parameter name Parameter number Parameter name Parameter number Parameter name Parameter
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter number Parameter name 5000 series FC 300 series 5000 series FC 300 series 513 Bus time interval Not converted Parameter number Parameter name 514 Bus time interval function Parameter number Parameter name 515 Reference % Parameter number Parameter name 516 Reference Unit Parameter number Parameter name 517 Feedback Parameter number Parameter name 518 Frequency 16-13 Frequency 5000 series FC 300 series 5000 ser
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – 5000 series Parameter number Parameter name 527 VLT® temp. Parameter number Parameter name Data values 528 Digital input Term. 16 (binary 0000 0001) Term. 17 (binary 0000 0010) Term. 18 (binary 0000 0100) Term. 19 (binary 0000 1000) Term. 27 (binary 0001 0000) Term. 32 (binary 0010 0000) Term.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – 5000 series FC 300 series Parameter number Parameter name 537 Heat sink temp Parameter number Parameter name 538 Alarm word Parameter number Parameter name 539 VLT® Control word Parameter number Parameter name 540 Warning word Parameter number Parameter name 541 Extended status word 14-74 VLT® Ext.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – VLT ® 5000 Group 6 5000 series FC 300 series Parameter number Parameter name 600 Operating hours Parameter number Parameter name 601 Hours run Parameter number Parameter name 602 kWh counter Parameter number Parameter name 603 Numbers of power up Parameter number Parameter name 604 Numbers of over temp.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter number Parameter name 5000 series FC 300 series 5000 series FC 300 series 613 Data log: Motor current Not converted Parameter number Parameter name 614 Data log: DC link voltage Parameter number Parameter name 615 Fault log: Error code Parameter number Parameter name 616 Fault log: Time Parameter number Parameter name 617 Fault log: Value Parameter number Parameter name Data value 618 Reset of kWh counter [0] No r
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter number Parameter name Parameter number Parameter name Parameter number Parameter name Parameter number Parameter name Parameter number Parameter name Parameter number Parameter name Parameter number Parameter name Parameter number Parameter name 5000 series FC 300 series 5000 series FC 300 series 5000 series FC 300 series 5000 series FC 300 series 5000 series FC 300 series 5000 series FC 300 series 5000 series FC 30
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – VLT ® 5000 Group 8 Parameter number Parameter name Parameter number Parameter name 5000 series FC 300 series 5000 series FC 300 series 5000 series FC 300 series 800 PROFIBUS DP 801 Baud rate selection Not converted Not converted Parameter number Parameter name 802 Minimum station delay Parameter number Parameter name Data range 803 Time out after bus error 1 – 99 803 Control Word Timeout Time 0.1 – 18000.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter number Parameter name Data value VLT 5000 series 849 Extended diagnose [0] Disable [1] Alarm [2] Alarm and warnings FC 300 series 807 Diagnosis Trigger [0] Disable [1] Trigger on alarm [2] Trigger on alarm/warn.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – 5000 series FC 300 series 5000 series FC 300 series Parameter number Parameter name 914 Broadcast off-set Parameter number Parameter name Data value 915 PCD config write [0] None [204] Minimum Reference [205] Maximum Reference [219] Catch up/slow Down Value [207] Ramp 1 Ramp up Time [208] Ramp 1 Ramp Down Time [209] Ramp 2 Ramp up Time [210] Ramp 2 Ramp down Time [211] Jog Ramp Time [212] Quick Stop Ramp Time [201] Motor Low Limit [
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – [520] Motor current [557] Motor RPM [526] Motor thermal [521] Torque [525] DC link voltage [536] Brake energy/s [535] Brake energy/2 min [537] Heat sink temp.
VLT® AutomationDrive PROFIBUS converter - Parameter Mapping List – Parameter name Status word (FMS) Parameter number Parameter name Data value 970 Parameter setup selection [0] Factory setting [1] Parameter setup 1 [2] Parameter setup 2 [3] Parameter setup 3 [4] Parameter setup 4 [5] Active setup Parameter number Parameter name Parameter type Data value 971 Save data values Unsigned 8 (5) [0] Not active [1] Save active setup [2] Save edit setup [3] Save all setups 971 PROFIBUS Save Data Values Unsig
VLT® AutomationDrive PROFIBUS converter - T r o u b l e s h o o t i n g - Troubleshooting Step-by-step troubleshooting After copying the station address from the VLT® 5000 to the ®FC 302, power must be cycled to the FC 302. The master/PLC should now recognize FC 302, as a VLT 5000, and the NS LED on the MCA114 option should now be solid green which indicates that communication between master and slave is established. • If the NS LED flashes, the master/PLC has not recognized the FC 302.
VLT® AutomationDrive PROFIBUS converter Index A Abbreviations 8 B Brake chopper 5 C Commissioning Configuration Constrains 12 11 6 D DIP switches 11 E EMC precautions 14 H Hardware 7 I Installation 9 L Linked setups Literature LEDs 7 7 13 M MCA114 Mechanical adaptation 9 7 N Node address 11 O Overview (technical) 5 P Parameters (mapping list) Performance Power size 15 7 5 S Safety 3 T Terminals Troubleshooting 6 58 W Warning word 58 MG.34.N1.