SDS

SDS Number: 00010501001 Revision Date: 11/3/2017
5. Fire-fighting Measures
UNUSUAL FIRE AND EXPLOSION HAZARDS: No Information
SPECIAL FIREFIGHTING PROCEDURES: Wear self-contained breathing apparatus pressure-demand (NIOSH approved or
equivalent) and full protective gear. Use water spray to cool exposed surfaces.
EXTINGUISHING MEDIA: Carbon Dioxide, Dry Chemical, Foam, Water Fog
6. Accidental Release Measures
ENVIRONMENTAL MEASURES: No Information
STEPS TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED: In case of spillage, absorb with inert material and dispose of in
accordance with applicable regulations.
7. Handling and Storage
HANDLING: KEEP OUT OF REACH OF CHILDREN!DO NOT TAKE INTERNALLY. Use only with adequate ventilation. Ensure fresh
air entry during application and drying. Do not breathe dust. Removal of this product after use will result in the generation of Dust. If
dry-sanded, exposure to dust may result in the build-up of material in eyes, ears, nose, and mouth which may cause irritation. While
dry sanding, use of a NIOSH-approved dust mask is recommended. Wash thoroughly after handling.
STORAGE: Avoid excessive heat and freezing. Do not store at temperatures above 120 degrees F. Store away from caustics and
oxidizers. Keep containers tightly closed.
8. Exposure Controls/Personal Protection
Ingredients with Occupational Exposure Limits
Chemical Name ACGIH TLV-TWA ACGIH-TLV STEL OSHA PEL-TWA
OSHA PEL-CEILING
Limestone N.E. N.E. 15 mg/m3 TWA
total dust, 5 mg/m3
TWA respirable
fraction
N.E.
Aqueous Acrylic Emulsion Polymer N.E. N.E. N.E. N.E.
Fly ash N.E. N.E. N.E. N.E.
Perlite N.E. N.E. N.E. N.E.
Titanium dioxide 10 mg/m3 TWA N.E. 15 mg/m3 TWA
total dust
N.E.
Quartz 0.025 mg/m3 TWA
respirable
particulate matter
N.E. 50 µg/m3 TWA N.E.
Further Advice: MEL = Maximum Exposure Limit OES = Occupational Exposure Standard SUP = Supplier's Recommendation
Sk = Skin Sensitizer N.E. = Not Established
Personal Protection
RESPIRATORY PROTECTION: When concentrations exceed the exposure limits specified, use of a NIOSH-approved
dust, mist and fume respirator is recommended. Where the protection factor of the respirator may be exceeded, use of
a full facepiece, supplied air, or Self Contained Breathing Apparatus (SCBA) may be necessary. If concentrations
exceed the exposure limits specified, use of a NIOSH-approved supplied air respirator is recommended. Where the
protection factor is exceeded, use of a Self Contained Breathing Apparatus (SCBA) may be necessary. Use an
approved NIOSH/OSHA respirator if dry sanded. National Institute for Occupational Safety and Health (NIOSH) has
recommended that the permissible exposure limit be changed to 50 micrograms respirable free silica per cubic meter of
air (0.05 mg/m3) as determined by a full shift sample up to 10-hour work shift. A respiratory protection program that
meets the OSHA 1910.134 and ANSI Z88.2 requirements must be followed whenever workplace conditions warrant a
respirator's use.
SKIN PROTECTION: Wear protective gloves.
Page 3 / 7