CAPACITIVE SETTINGS & CONNECTIONS
Sensitivity adjustment
The sensitivity adjustment must be done when the
sensor is installed in a definite and steady position.
The regulation must be done in a position half way
between minimum and maximum, because, being air
dielectric, a strong humidity variation could cause,
if the regulation is very light, nuisance tripping.
The sensing distance of the sensor depends on the
materials to detect, on its dimension and conductivity.
The distance could change according to temperature
variations.
Timer adjustment
The timer trimmer allows to set a delay, on the
activation (delay ON) or in the de-activation of the
output, depends on the model, after the detection of
the object. The output will remain active (or inactive)
proportionally to the setting point of the screw,
starting from 1 second up to 5 minutes.
2 wires Vac models
6 wires Mulivoltage models
M8 4-pole NO-NC models
4 wires NO-NC Vdc model