Instruction Manual

18
M2 User Manual
Push “SELECT” to continue.
A L A R M O U T P U T 6
> M C - A V < D L A Y O F F
If “MC-AV” or “DLAY” is selected, submenu for “Alarm Delay” with “30”, “60”, “120”
and “240” second options is displayed next. Use UP and DN switches to toggle the
setting and highlight the desired option.
A L A R M D E L A Y
3 0 > 6 0 < 1 2 0 2 4 0 S
Push “SELECT” switch to save and increment the menu to the next alarm function.
Audible Alarm Buzzer
Highlight desired “ON” or “OFF” option using UP and DN switches to toggle the
setting. Select “ON” for audible alarm to beep during any active alarm condition and
continue with alarm configuration menu; select “OFF” for audible alarm to be silent
during any active alarm condition.
A L A R M B U Z Z E R
> O N < O F F
Push “SELECT” to continue.
Alarm Configuration Enable or Save
Highlight desired “ENABLE” option to arm selected alarms and save alarm
configuration or “SAVE” option to save alarm configuration without arming alarms.
Use UP and DN switches to toggle the setting.
A L A R M C O N F I G
E N A B L E > S A V E <
Push “SELECT” to continue. The alarm configuration settings are saved in non-volatile
memory.