User and Installation Guide

Table Of Contents
17
INSTALLATION
Gas Hook-up
Connection: LP Hose with a Type 1 quick disconnect and regulator is included. Operating pressure:
11.0”W.C. All gas piping and connectors must conform to the Standard for Connectors for Outdoor
Gas Appliances and Manufactured Homes, ANSI Z21.75/CSA 6.27.
If you intend to operate your built-in grill on LP gas utilizing a 20v lb type 1 cylinder, then a built-
in LP tank restraint must be installed prior to initial use of the grill. The Installer must supply ½” ID
Flex hose and fixed pipe and a flare adaptor as indicated in Fig. 09.
Note:
when an LP unit is being directly connected to an LP house system, you must follow the natural
gas hook up guidelines.
The installer must provide the proper gas regulator to reduce the gas pressure to 11” W.C.
LP built-in hook-up
If the grill is to be installed in a built-in application, then the grill must be installed in accordance with
the built–in installation guidelines and
the LP regulator/hose assembly must be removed from the
product
.
IMPORTANT!
Gas piping and connectors must be clamped within the the enclosure to avoid contact with moving
parts and hot surfaces. Where the gas piping passes through an opening in the enclosure, the
piping must be protected for a distance of at least 2” (50mm) either side of the opening.
Bottom of unit
LP regulator/
hose assembly
Enclosure wall
1/2” ID flex hose with
1/2” NPT fittings
(not supplied)
1/2” NPT fixed pipe
(not supplied)
Adapter 3/8”
flare fitting
1/2” NPT female
(not supplied)
20 lb
LP Tank
(not supplied)
Tank retention
device (not
supplied)
FIG. 09 LP Gas - Built-in
EN