Install Guide

6
BUILT-IN CONSTRUCTION
CAVITY DIMENSIONS
PBE1 MODELS
INCHES MM
A Height of cutout 10 1/8 257
B Depth of cutout 22 3/4 578
C Width of cutout
22 1/2
572
D Depth of gas supply opening 4 102
E Width of gas supply opening 4 15/16 125
a
b
c
d
e
ventilation
a
b
c
d
f
g
e
ventilation
As the power burner is designed for larger cookware, sufficient space should be left around the product for safe handling.
Notes:
When determining a suitable location, take into account concerns such as exposure to wind, proximity to traffic paths,
and keeping any gas supply lines as short as possible.
Locate the unit in a well-ventilated area.
The counter and supporting ledges or deck must be level and flat.
The enclosure should have ventilation holes to prevent gas build-up in the event of a leak. Refer to ANSI Z21.58
Standard for Outdoor Cooking Gas Appliances, Section 1.7 Enclosures For Self Contained LP-Gas Supply Systems.
Notes:
To purchase access doors and drawers, visit dcsappliances.com
24” access doors model number: ADN1-20x24
24” access drawers model number: ADR2-20x24
CUTOUT DIMENSIONS
PBE1 MODELS
INCHES MM
A Height of cutout 11 1/8 283
B Depth of cutout 23 3/4 603
C Width of cutout 28 7/8 734
D Depth of gas supply opening 4 102
E Width of gas supply opening 4 102
F Depth to gas supply opening from front of cutout 18 1/2 470
G Width to gas supply opening from side of cutout 3 1/2 89
COUNTER TOP LEVEL CUTOUT COUNTER TOP LEVEL INSULATED JACKET CUTOUT
If the unit is to be placed into a combustible enclosure, an insulated jacket is required.