Installation for Framed Cabinetry

13
6 CAVITY PREPARATIONS
CAVITY DIMENSIONS inches (mm)
A
Overall height of cavity 80/84” (2032/2134)
B
Overall width of cavity 36” (914)
C
Overall depth of cavity 24 3/4” (629)
ELECTRICAL SPECIFICATIONS
Supply 115VAC, 60Hz
Service 10 amp circuit
PLUMBING SPECIFICATIONS
Supply 1/4” (6mm) comp. stainless steel braided hose
Pressure min 22psi (150kPa)
max 120psi (827kPa) @ 68°F (20°C)
Note: electrical connection can be located in an adjacent cabinet to either side of the fridge or above the fridge cavity.
A
C
B
Floor
2 7/8” (73mm)
29 3/4” (756mm)
5 5/8” (143mm)
Left side of cavity
Electrical and water connections must be within
this space if located behind the refrigerator
REAR OF CAVITY
2” (51mm)
IMPORTANT!
For ease of installation, ensure cavity width is consistent top to bottom and height is
consistent left to right.
For integrated installation, ensure dimensions of finished return dimensions are as shown.
A
C
B
Alternative area above cavity
for electrical connections
Electrical
Plumbing
Electrical
Plumbing
Framed: Finished return
top and sides
Framed: Finished return
sides and top
3 1/2”
(89mm)