Xantrex Technology Inc. Toll free 1 800 670 0707 Direct 1 360 925 5097 Fax 1 360 925 5143 customerservice@xantrex.com www.xantrex.
Remote Control Panel Control your Xantrex Freedom Inverter/Charger DC system monitoring of DC Volts, Battery Charger output current, Inverter input current and Battery State Adjustable features of Power Share Battery Type and Idle Mode settings. Additional features on Freedom 458 and Marine Series include Battery Capacity setting. Easy to install Manual Contents Installation..........................................................................3 Operation......................................
Limited Warranty What does this warranty cover? This Limited Warranty is provided by Xantrex Technology, Inc. (Xantrex) and covers defects in workmanship and materials in your Xantrex Freedom Inverter/Charger Remote Control Panel. This warranty lasts for a Warranty Period of 12 months from the date of purchase at point of sale to you, the original end user customer. This Limited Warranty is transferable to subsequent owners but only for the unexpired portion of the Warranty Period.
SETUP Blinking indicates SETUP mode. SETUP is explained on page 5. When the CHARGE LED is On (solid green), the Battery CHARGE Charger is On and charging. When the LED is Off, the charger is Off. Charging automatically begins when external AC power is detected. OPERATING TIP: Leaving the charger ON helps to assure a full battery. When the INVERT LED is On (solid green), the Freedom INVERT Inverter is inverting (making AC power from the DC battery source). When the INVERT LED is Off, the inverter is Off.
8 Error Detected Possible Solution Fault LED LED Indication OVERTEMP On OFF Over-temperature shutdown. Increase air circulation and allow to cool. BATTERY STATE Empty blinking ON Low Battery Shutdown. (too low to continue inverting) Charge batteries. BATTERY STATE Empty On ON Battery Overload. (excessive ripple voltage during charge) Select lowest Power Share setting. Turn off DC Loads. Restart Charger. 15.5 VDC blinking (31.0 VDC in 24 V system) ON High battery shutdown.
SET TYPE Battery Type This setting is important. Check your settings. Using POWER SHARE, set the Battery Type. The charger uses this information to set charging values for the 3-stage automatic charger. Be sure to set the correct type. Default: Freedom: Cool (<80 °F) Wet cell, 458 Series: Wet cell Setting the Battery Type correctly is important. Cool Wet Cell: Warm Wet Cell: Cool Gel Cell: Warm Gel Cell: < 80 °F. > 80 °F. < 80 °F. > 80 °F. 458 Series selections: Wet, Gel 1, Gel 2 or AGM.