Owner`s manual

Blinking indicates SETUP mode.
SETUP is explained on page 5.
94
When the INVERT LED is On (solid green), the Freedom
Inverter is inverting (making AC power from the DC battery
source). When the INVERT LED is Off, the inverter is Off.
When external AC power is present (AC IN LED On) and the INVERT
LED is blinking green, the inverter is in standby, waiting for external AC
power to be removed to begin inverting. When there is no external AC
power, a blinking green LED indicates the inverter is in the Idle Mode.
Idle mode is explained in detail in the SETUP section. OPERATING
TIP: To avoid the risk of discharging your batteries if external power
fails, leave the inverter OFF when leaving the boat or RV unattended.
INVERT
SETUP
external AC power is detected. OPERATING TIP: Leaving the charger
ON helps to assure a full battery.
When the CHARGE LED is On (solid green), the Battery
Charger is On and charging. When the LED is Off, the
charger is Off. Charging automatically begins when
CHARGE
REMOTE POWER SHARE USED BY FREEDOM (SN < 100,000)
POWER MODEL: F10 F20 F25 F25
SHARE SN: <100,000 <70699 <70801 >70802
50 NA NA OFF OFF
30 30 30 NA NA
20 20 20 50 30
15 15 15 30 20
5 10 10 20 5
plug into a 30 ampere external AC power source, press POWER
SHARE until the 30 amp INCOMING AC BREAKER LED is ON.
OPERATING TIP: If the breaker trips, reduce this setting. Setting the
POWER SHARE feature to a lower setting may limit charger output,
causing the batteries to require more time to become fully charged.
POWER SHARE limits the amount of external AC current used by the
charger. If the total AC load is larger than the AC power available, the
external AC circuit breakers may trip. Select a lower POWER SHARE
setting to reduce AC power consumption by the charger, thus reducing
the total AC load.
Available POWER SHARE settings vary by inverter/charger model. Only
the settings that the inverter/charger supports are allowed. The following
table shows the effective power share for a Freedom Inverter/Charger with
a serial number less than 100,000.
Before you plug into an external AC source, note the
breaker size. Press POWER SHARE until the appropriate
INCOMING AC BREAKER LED is On. For example, to
POWER
SHARE
Specifications
Model: 84-2056-01: 12 V Control Panel w/25' data cable
Size: 5 3/4'' (L) X 3 3/4'' (W) X 1'' (D)
Cutout Size: 4.7/8'' (W) X 2 7/8'' (H)
Environmental: Splash resistant
Operating temp: 070 °C
Weight: 3 Oz.
Power: Power for the Remote Control Panel is supplied
by the Freedom Inverter/Charger.
Export Model
The export model has power share levels of 2.5, 7.5, 10, 15, and 25
amps. The following table shows the effective power share if a Freedom
Inverter/Charger with a serial number less than 100,000 is used.
REMOTE POWER SHARE USED BY FREEDOM
POWER MODEL: F10E (EXPORT)
SHARE SN: 70746
20 NA
16 30
10 20
6 15
4 5
<