Data Sheet

22.10.2019
15W~24W
Wall mount
SYS1308N-Wxx series
Country of Origin :
Operating Temperature :
Dimension :
Efficiency level (ErP) :
Approvals / Marks :
China
0~40 [°C]
75 x 34 x 43 [mm]
VI
www.sunny-euro.com
RoHS
GREEN MODE
Specifications
Model
Voltage DC
[V]
Loading
[A]
Max. Power
[W]
Ripple / Noise
[mV] p-p
Connector
[mm]
SYS1308N-1505-Wxx 5 0~3.00 15 150 2.1x5.5x11
SYS1308N-1807-Wxx 7.5 0~2.40 18 180 2.1x5.5x11
SYS1308N-1809-Wxx 9 0~2.00 18 180 2.1x5.5x11
SYS1308N-2412-Wxx 12 0~2.00 24 200 2.1x5.5x11
SYS1308N-2415-Wxx 15 0~1.60 24 200 2.1x5.5x11
SYS1308N-2418-Wxx 18 0~1.33 24 240 2.1x5.5x11
SYS1308N-2424-Wxx 24 0~1.00 24 240 2.1x5.5x11
SYS1308N-2448-Wxx (ErP V. / CE only) 48 0~0.50 24 480 2.1x5.5x11
Features:
Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2A - Australia | W2K - Korea | W2C - China
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT
Turn delay
3000ms max 3S max on the condition that input volotage 230V,
full load.
Hold up time
5ms min@AC nominal input@output full load
Efficiency
>81.39% min. Eff= 0.071 x In(Po/1W) - 0.0014 x Po/1W + 0.67
Directive EU 2019/1782
Transient response
(dv,tmax)
0.6V dv max At AC nominal input loading from 20%load to 80%
load
10ms tmax Dynamic rise time 10 us max,duty 40ms
max,Dynamic load step is slew rate of 0.5A/us
Burn in limit
Ambient temp: 35C+-3%; 80% load; input voltage 230V; 2 hours.
Power consumption
0.1W max. At AC nominal input@output min load
INPUT
Voltage
(90~264)VAC
Frequency (47 ~ 63)Hz
Current
1A rms@AC low line input and DC output full load
Inrush Surge Current
(cold start)
60A max@power supply cold start, ambient temperature 25°C
@100Vac/240Vac nominal AC input
leakage current <0.25 mA @ 240VAC input
PROTECTION
Over current/
Short protection
The power supply will self-protect any output to ground, And auto
recovery when abnormal circuit faults remove. An output short
circuit is defined as any output impedance of less than 0.1 ohms.
Over Voltage
The power supply will not be auto recovered when faults remove
110%-150%. (Voltage limit)
Input protection
2A /250V Fuse. The power supply shall be protected against
power line surges and any abnormal condition
No Load protection
The power supply is provided with no load operation to prevent
the power supply and system from damage.
Protection class
II
CE
EMC
2014/30/EU
LVD
2014/35/EU
EN 62368-1
SAFETY
CE | CB | TUV/GS
OTHERS
Dielectric Strength
(Hi-pot)
HI-POT B / IEC 320 2pin primary to secondary 4000Vdc 10mA
1min
M.T.B.F
500,000 Calculated Hours at 25ºC, by Telcordia SR -332
Cable Length
1830mm (6 feet) standard cable or as required
PLD
(power line disturbance)
Line power surge | Line voltage SAG-more info on request
Cooling method
Natural Convection Cooling
Housing material
PC
Temperature coefficient:
<±0.5%/°C
ENVIRONMENT
Temperature
Operating: 0~40 / Storage: -20%~85%RH non condensing
Humidity
Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
WEIGHT
NW: 105g/pc + plug
GW: 122g/pc + plug
PACKING
Box
80 pcs/1 box