Installation - Models 203, 204, 204P, 240, 242, 248, 250, 305 And 307
Location
Units in this manual are intended for indoor use only.
Avoid hot corners and locations near stoves and ovens.
Counter Cutouts
For installation, provide a cutout in the counter sized
according to the chart below. The counter must be
sturdy enough to hold the combined weight up to 300
pounds of the drop-in and the product stored inside.
22.00” (55.9cm)
204/204P Stud Location
19.25” (48.9cm)
204/204P Stud Location
29.50” (74.9cm)
248 Stud Location
13.50” (34.3cm)
13.25” (33.7cm)
305 Stud Location
19.375” (49.2cm)
305 Stud Location
10.12” (25.7cm)
307 Stud Location
10.12” (25.7cm)
307 Stud Location
Model Cutout Size Mounting
Studs
1/2” IPS
Water
Hookup
Drain
203
ice chest 19.25” x 19.25”
(48.9cm x 48.9cm)
N/A N/A (1) 1”
204
water and ice
station
21” x 17.75”
(53.3cm x 45.1cm)
4 1 (2) 1”
204P
water and ice
station
21” x 17.75”
(53.3cm x 45.1cm)
4 1 (2) 1”
240
ice chest with cover N/A N/A N/A (1) 1”
242
UC sink & faucet 17” x 12.5”
(43.2cm x 31.8cm)
N/A 2 (1) 1-1/2”
248
water and ice
station
28” x 12.5”
(71.1cm x 31.8cm)
4 1 (2) 1”
250
UC sink, ice chest
and water station
45” x 13”
(114.3cm x 33.0cm)
N/A 3 (2) 1”
(1) 1-1/2”
305
ice chest with cover 12.5” x 17.75”
(31.8cm x 45.1cm)
4 N/A (1) 1”
307
glass filler 9.00” x 9.00”
(23cm x 23cm)
4 1 (1) 1”
Mounting Studs
Equipment with mounting studs are pictured below.
Mark the stud locations according to the measurements
or place the equipment in the cutout to mark the stud
locations. Drill 0.37” (1.0cm) diameter holes through the
counter for the studs.
Drain
Provided 1” (2.5cm) drain, nut and washer must be
eld installed to an appropriate container or oor drain
following local code requirements. Sinks come standard
with 1-1/2” basket strainer assemblies.
Water Connection
All 1/2” (1.3cm) IPS water inlets must be eld connected
following local code requirements.