Installation manual

Dispensing Models Service and Installation Manual
13
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
Adjusting the self-leveling dispenser
Tools Needed: One small flat head screw driver;
One Phillips head screw driver
1. Always wear safety glasses when adjusting your dispenser.
Also, lock brakes on mobile units before beginning.
2. Unload dispenser and remove stainless steel load tray by
lifting straight up and set it aside (see fig. 1). For Models
LT skip to step #6.
3. Use small regular screw driver to loosen each retainer
mounted on stainless steel rod at top of each elevator
housing.
4. To remove
elevator housing,
lift housing
straight up to
clear the stud on
unit base. Then
gently swing the
bottom of the
housing towards
the inside of the
unit and pull
housing out of
the unit (see fig.
2). Lay housing
on flat surface.
5. Use Phillips head
screw driver to remove
front panel on the
elevator housing (see
fig. 3).
6. If carrier is riding
too high, you need
to remove springs.
With carrier all the
way to the top, gently
disengage one spring
at a time, unhooking
bottom loop out of
carrier bracket (see fig.
4). Remove as many
springs as necessary.
If carrier is riding too
low, you need to add
springs. With carrier
all the way to the top,
gently engage one
spring at a time by
hooking bottom loop
of spring into carrier
bracket. Add as many
springs as necessary.
7. When finished, put
elevator housing back in unit (except on models LT) and
put stainless steel load tray back on elevator housings.
Load unit to test dispensing level. If spring adjustment
does not position carrier properly, repeat procedure #6
trying different springs. If this does not work, a different
set of springs may be required. To order, call The Delfield
Parts and Service Department.
8. If level is appropriate, put front panels back on and
tighten retainer.
Dispenser should not be operated with front
panels off elevator housing.
NOTE:
When adjusting the elevators make sure each have the
same number and size of springs connected to the carrier on
both sides. This will prevent the load tray from binding.
(figure 1) Sample unit
(figure 2) Remove elevator housing
(figure 3) Remove front panel
(figure 4) Remove or add springs
CAUTION
ADJUSTING SELF-LEVELING DISPENSERS