Installation manual

Dispensing Models Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
8
The thermostat is located on the bottom of the unit near
the fan motor. Use the following directions to adjust.
Unplug the unit and allow the unit to cool
completely before handling.
1) Lock brakes on mobile units before beginning.
2) Unload the dispenser. Remove dispensers from the unit
by grasping the black plastic guide posts and lifting the
dispenser completely out of the unit. It is not necessary to
remove the steel jacket from the dispensing tube.
3) Turn the unit on its side.
4) Remove filter from
bottom of unit. It
is not necessary
to remove the
perforated screen.
The screen has
access holes in it to
allow adjustment
of the thermostat.
The screen is
shown removed in
diagram 3 to show
the location of the thermostat adjustment screw only.
5) Use a small screw-driver to reach the adjustment screw
located under the perforated screen (see diagram 3). Turn
the screw to the desired setting based on the “thermostat
settings chart” shown below.
6) Reattach the filter before operating the unit again.
DA RNGE
(diagram 3)
Location of thermostat adjustment screw
Heated Unit Thermostat Settings
Temperature Setting
Operating Temperature (°F)
Operating Temperature (°C)
"A"
165
74
"B"
175
79
"C"
185
85
"D"
195
91
"E"
205
96
OPERATION: DISH DISPENSERS (CONTINUED)