26 Fabric OS Troubleshooting and Diagnostics Guide
53-1002930-01
Connection problems
3
Checking the logical connection
1. Enter the switchShow command.
2. Review the output from the command and determine if the device successfully logged in to the
switch.
A device that is logically connected to the switch is registered as an F_Port, L_Port, E_Port,
EX_Port, VE_Port, VEX_Port, or N_Port.
A device that is not logically connected to the switch is registered as a G_Port or U_Port, if
NPIV is not on the switch.
3. Enter the slotShow -m command to verify that all blades are enabled and not faulty, disabled,
or in some other non-available state.
4. Perform the appropriate actions based on how your missing device is connected:
If the missing device is logically connected, proceed to the next troubleshooting procedure
(“Checking the Name Server” on page 27).
If the missing device is not logically connected, check the device and everything on that
side of the data path. Also refer to “Link failures” on page 28 for additional information.
Checking the path includes verifying the following for the host:
The host OS is configured correctly.
The third-party vendor multi-pathing input/output (MPIO) software, if it is being used,
is configured correctly.
The HBA and storage device and the driver and firmware are compatible with the
switch based on the compatibility matrix.
The driver settings and binaries are up-to-date.
The device Basic Input Output System (BIOS) settings are correct.
The HBA configuration is correct according to manufacturer’s specifications.
The SFPs in the HBA are compatible with the host’s HBA.
The SFP on the switch is compatible with the switch.
The switch settings related to the host are configured correctly.
Checking the path includes the following for the target:
The driver settings and binaries are up-to-date.
The device Basic Input Output System (BIOS) settings are correct.
The HBA configuration is correct according to the manufacturer’s specifications.
The SFPs in the HBA are compatible with the target HBA.
The switch settings related to the target are configured correctly.
Refer to “Checking for a loop initialization failure” on page 29 as the next potential trouble
spot.