Quick Reference Guide

NOTE:
The OMSA server agent must be present and
running on the server to use the Display Hostname
feature. If the agent is not running, the setting is
ignored. For more information, see the
Dell
OpenManage Server Administrator User's Guide
at
support.dell.com/manuals.
Synopsis
racadm setslotname -i <slotID>
<slotname>
racadm setslotname -h <enabled>
Input
<
slotID
> — Displays the location of the slot in the
chassis.
Legal values: 1–16
<
slotname
> — The new name to be assigned to
the slot.
<
enabled
> — Sets whether the server's hostname
is used for display purposes.
Legal values: 0, 1
Example
racadm setslotname -i 3 mserver3
The slot name was set successfully.
setsysinfo
Description Sets the name or location of the chassis.
To use this subcommand, you must have Administrator
privilege.
This command is applicable only for CMC.
Synopsis
racadm setsysinfo -c chassisname|
chassislocation <string>
Input
<
string
> — Indicates a maximum of 64 non-
extended ASCII chassis name or location.
-c — Sets the chassis name or location.
Example
racadm setsysinfo -c chassisname "Dell
Rack System"
The chassis name was set successfully.
sshpkauth
Description Enables you to upload and manage up to 4 different SSH
public keys per user. You can upload a key file or key text,
view keys, or delete keys.
This command has three mutually exclusive modes—
upload, view, and delete that are determined by the
options.
112