Quick Reference Guide

NOTE:
For iDRAC Enterprise on Blade Servers, this
object enables or disables the VLAN capabilities of
iDRAC from CMC.
This is Read only for iDRAC on Blade servers.
iDRAC displays only the current VLAN settings and you
cannot modify the settings from iDRAC.
All chassis management traffic, including the CMC and all
iDRACs, resides on this external VLAN when enabled. No
iDRAC configuration change is required to use this
external management network VLAN.
Legal Values
1 (TRUE)
0 (FALSE)
Default 0
Example
racadm config -g cfgLanNetworking -o
cfgNicVLanEnable
1
racadm config -g cfgLanNetworking -o
cfgNicVLanEnable
0
cfgNicVLanId (Read or Write)
Description Specifies the VLAN ID for the network VLAN configuration
(in CMC for iDRAC Enterprise on Blade Servers). This
property is only valid if cfgNicVLanEnable is set to 1
(enabled).
This is Read only for iDRAC on Blade servers.
Legal Values 1 – 4000 and 4021 – 4094
Default 1
Example
racadm config -g cfgLanNetworking -o
cfgNicVlanID
1
cfgNicVLanPriority (Read/Write)
Description Specifies the VLAN Priority for the network VLAN
configuration (in CMC for iDRAC Enterprise on Blade
Servers). This property is only valid if
cfgNicVLanEnable is
set to 1 (enabled).
This is Read only for iDRAC on Blade servers.
Legal Values 0 - 7
Default 0
Example
racadm config -g cfgLanNetworking -o
cfgNicVLanPriority 7
134