Quick Reference Guide

cfgServerPowerSupplyFwVer (Read Only)
Description Displays the firmware version of the power supply unit, in
the format x.xx.xxx.
Legal Values A string up to 8 characters.
Default Null
cfgServerPowerSupplyCurrentDraw (Read Only)
Description Displays the instantaneous current consumption in 0.1
Amps.
Legal Values A string of up to 32 characters.
Default 0
cfgServerPowerSupplyType
Description Displays whether the power supply is AC or DC.
Legal Values A string of up to 32 characters.
Default 0
cfgIPv6LanNetworking
This group is used to configure the IPv6 over LAN networking capabilities.
Use this object with the config
or getconfig subcommands.
To use this object property for CMC, you must have Chassis Configuration Administrator privilege.
NOTE:
Use the -m option to apply this setting to iDRAC.
The following sections provide information about the objects in the cfgIPv6LanNetworking group.
cfgIPv6Enable (Read/Write)
Description Enables or disables iDRAC or CMC IPv6 stack.
Legal Values
1 (TRUE)
0 (FALSE)
Default 0
cfgIPv6Address
Description Assigns a static IPv6 address to the CMC. This property is used only if
cfgIPv6AutoConfig is set to 0 (false).
211