Quick Reference Guide

NOTE:
This value is applicable only if System.Power.Cap.Enable is set to 1.
Legal Values Values from 0 - 100
Default Value Server power threshold in watts
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Dependency System.Power.Cap.Enable must be enabled
System.Power.EnergyConsumption (Read Only)
Description Represents the Cumulative power consumption by the blade or
system.
Legal Values Values from 1 - 65535
Default Value Cumulative power consumption.
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Dependency None
System.Power.EnergyConsumption.Clear (Read or Write)
Description Clears the cumulative power consumption timestamps.
Legal Values 1
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Dependency None
System.Power.EnergyConsumption.StarttimeStamp ( Read Only )
Description Displays the Timestamp of the cumulative power consumption.
Legal Values String of up to 254 ASCII characters
Default Value Timestamp of the cumulative power consumption.
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Write Privilege None
System.Power.Hotspare.Enable (Read or Write)
Description Enables HotSpare functionality for the primary PSU selection.