Quick Reference Guide

More than 1 bit can be set at a time to indicate multiple
redundancy support.
0 - not applicable
1 - Non Redundant
2 - 1+1 Redundant
4 - 2+1 Redundant
8 - 2+2 Redundant
16 - 3+x Redundant
32 - 4+x Redundant
64 - 5+x Redundant
Default Value 0 - not applicable
System.Power.RedundantState (Read Only)
Description Retrieves the redundancy state for the chassis.
Legal Values
0 - None
1 - Full
Default 0
System.Power.Supply
This group provides information relating to the Power Supplies.
This group is indexed from 1 to 4. If there are less than 4 power supplies on the server, then some of the last indexes of
this group are not applicable. This group is not applicable for iDRAC on Rack and Tower servers.
The following section provides information about the objects in the <System>.Power.Supply group.
System.Power.Supply.CurrentDraw (Read Only)
Description Displays the instantaneous current consumption in 0.1
Amps.
Legal Values String of up to 254 ASCII characters
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Dependency None
System.Power.Supply.FwVer (Read Only)
Description Displays the firmware version of the power supply unit.
Legal Values String up to 254 ASCII characters.
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
249