Quick Reference Guide

Example
Set root password, configure static IPV4 address, set first boot device to
HDD, and enable boot once for server-1.
racadm deploy -m server-1 -s 192.168.0.20
255.255.255.0 192.168.0.1 HDD -o yes
Set root password, configure static IPV6 address, set first boot device to
HDD, and enable boot once for server-1.
racadm deploy -m server-1 -s 192.168.0.11
255.255.255.0 192.168.0.1 HDD -o yes
Set root password and enable DHCP for server-3.
racadm deploy -m server-3 -u root -p <passpwrd> -d
Set user name and password for switch-2.
racadm deploy -m switch-2 -u <username> -p
<password>
Set SNMP community string for switch-2.
racadm deploy -m switch-2 -v SNMPv2
DemoCommunityString ro
Set root password to calvin for all servers.
racadm deploy -a -u root -p calvin
Set user name and password for all switches.
racadm deploy -a switch -u <username> -p <password>
eventfilters
Description Gets, sets, tests the alerts for message ID, and displays the list of event filter settings.
To use this subcommand with the get
and test option, you must have Administrator
privilege.
This subcommand is applicable only for iDRAC.
Synopsis
racadm eventfilters <eventfilters command type>
racadm eventfilters get -c <alert descriptor>
racadm eventfilters set -c <alert descriptor>-a <action>-n
<notifications>
racadm eventfilters set -c <alert descriptor>-a <action>-r
<recurrence>
racadm eventfilters test -i <Message ID to test>
NOTE:
The general format of an alert descriptor:
idrac.alert.category.[subcategory].[severity]
where, category is mandatory, but subcategory and severity are optional. A severity
cannot precede a subcategory.
Valid Category values are:
All
System
Storage
Updates
Audit
Config
31