Quick Reference Guide
• Worknotes
Valid Severity values are:
• Critical
• Warning
• Info
Valid examples of alert descriptors are:
• idrac.alert.all
• idrac.alert.audit
• idrac.alert.audit.lic
• idrac.alert.audit.warning
• idrac.alert.audit.lic.critical
Input
• get — Displays the list of eventfilter settings.
• set — Configures the actions and notifications for a given eventfilter
configuration.
• -i — Message ID for which the simulation is needed.
• -c — Alert descriptor of the specific event filter.
• -a — The action that must be invoked when the event occurs. Valid values are
none, powercycle, poweroff, or systemreset.
• -n — The notification is sent when the event occurs. Valid values are all, snmp,
ipmi, lcd, email, remotesyslog, or none. You can append multiple notifications
separating by a comma. You cannot enter the values
all or none with other
notifications.
• -r — Event generation interval. This option is applicable only to the temperature
statistics subcategory — tmps. You can use this option as a stand-alone or with -
n and
-a.
NOTE:
If both event generation interval and notifications are configured and there is
an error while configuring the notifications, the event generation interval is not set.
The valid values are 0–365. 0 disables the event generation.
Example
• Display all available event filter configurations:
racadm eventfilters get -c idrac.alert.all
• Display eventfilter configurations for a specific category. For example, audit:
racadm eventfilters get -c idrac.alert.audit
• Display eventfilter configurations for a specific subcategory. For example,
licensing under the audit category:
racadm eventfilters get -c idrac.alert.audit.lic
• Display eventfilter configurations for a specific severity. For example, warning
under the audit category:
racadm eventfilters get -c idrac.alert.audit.warning
• Display eventfilter configurations for a specific severity and subcategory. For
example, a severity of warning in the subcategory licensing under audit
category:
racadm eventfilters get -c
idrac.alert.audit.lic.warning
• Clear all available alert settings:
racadm eventfilters set -c idrac.alert.all -a none -n
none