Quick Reference Guide

Module ID = ps-6
Severity = Critical
Message = The power input for power supply 6 is lost.
To display critical error messages for server-1:
racadm getactiveerrors –s critical –m server-1
There are no critical alerts
Module ID = server-1
Severity = Critical
Message = The storage battery has failed.
The error message displayed for invalid syntax.
racadm getactiveerrors –z cmc-1
ERROR: The syntax of the command specified is not correct.
The error message displayed for invalid parameter.
racadm getactiveerrors –m server-80
ERROR: The syntax of the command specified is not correct.
To display entire information log.
racadm getactiveerrors -s info
Module ID = server-1
Severity = Critical
Message = A fabric mismatch deteceted for mezzanine card B1.
Module ID = ps-1
Severity = Critical
Message = The power input for power supply 1 is lost.
Module ID = ps-3
Severity = Critical
Message = The power input for power supply 3 is lost.
Module ID = cmc-1
Severity = NonCritical
Message = A firmware or software incompatibilty detected
between system BIOS in slot 4 and CMC.
getarraycfg
Description This command is applicable only for CMC. Use this command to display the storage
array properties and configuration status.
Synopsis
getarraycfg -m <module> [-s]
Input
-m — The valid value for
—m <module> is server-n, where n = 1 to 16.
-s — query for current storage configuration process status.
Output Array configured properties for:
Member Name
Member IP
Group Name
Group IP
Fabric Selection
42