Quick Reference Guide
Module ID = ps-6
Severity = Critical
Message = The power input for power supply 6 is lost.
• To display critical error messages for server-1:
racadm getactiveerrors –s critical –m server-1
There are no critical alerts
Module ID = server-1
Severity = Critical
Message = The storage battery has failed.
• The error message displayed for invalid syntax.
racadm getactiveerrors –z cmc-1
ERROR: The syntax of the command specified is not correct.
• The error message displayed for invalid parameter.
racadm getactiveerrors –m server-80
ERROR: The syntax of the command specified is not correct.
• To display entire information log.
racadm getactiveerrors -s info
Module ID = server-1
Severity = Critical
Message = A fabric mismatch deteceted for mezzanine card B1.
Module ID = ps-1
Severity = Critical
Message = The power input for power supply 1 is lost.
Module ID = ps-3
Severity = Critical
Message = The power input for power supply 3 is lost.
Module ID = cmc-1
Severity = NonCritical
Message = A firmware or software incompatibilty detected
between system BIOS in slot 4 and CMC.
getarraycfg
Description This command is applicable only for CMC. Use this command to display the storage
array properties and configuration status.
Synopsis
getarraycfg -m <module> [-s]
Input
• -m — The valid value for
—m <module> is server-n, where n = 1 to 16.
• -s — query for current storage configuration process status.
Output Array configured properties for:
• Member Name
• Member IP
• Group Name
• Group IP
• Fabric Selection
42